Search PubMed⌕ Search

PubMed · 15868114

Introduction.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Dahlöf, E Ritz. 2005. Introduction.. https://doi.org/10.1007/s00592-005-0174-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Exploring series of multivariate censored temporal data through fuzzy coding and correspondence analysis.

We present an exploratory analysis methodology for a multiple series of multivariate temporal data subject to censoring, and thus requiring the introduction of a coding technique: fuzzy coding preserving a large amount of the distributional information is fully adapted. Correspondence analysis is performed on the array produced by fuzzy coding. Projections of mean paths on factorial mappings, according to subgroup characteristics, highlight the behaviour of the underlying process. This approach is illustrated with an application to a randomized controlled clinical trial designed for comparing non-diabetic chronic renal failure treatments. Our methodology has resulted in the identification of a difference between the treatments with an interpretation of the effects in subgroups of patients not obtainable with traditional survival methodology; it also provides some valuable insights for designing further studies on treatment of renal impairment.

Angiotensin-Converting Enzyme Inhibitors↗

First LC-MS/MS electrospray ionization validated method for the quantification of perindopril and its metabolite perindoprilat in human plasma and its application to bioequivalence study.

A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.

Angiotensin-Converting Enzyme Inhibitors↗