Search PubMed⌕ Search

PubMed · 1580460

Reviewer bias.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ernst, K L Resch, E M Uher. 1992-06-01. Reviewer bias.. https://doi.org/10.7326/0003-4819-116-11-958_2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Depiction of low-contrast detail in digital radiography: comparison of powder- and needle-structured storage phosphor systems.

PURPOSE: We sought to evaluate the low-contrast performance of a newly developed needle image plate/line scanner (NIP) computed radiography system in comparison with a standard powder image plate/flying-spot scanner (PIP) system. MATERIALS AND METHODS: A total of 36 images of a CDRAD phantom, simulating low-contrast structures with different drill holes of different diameters, were obtained with both imaging systems using 9 different exposure variables. All images had window and level set to generate consistent density and contrast. In addition, multiscale contrast-dependent contrast amplification was applied to some of the images. All images obtained were printed and presented to a total of 10 observers (5 radiologists, 5 engineers/physicists), who were blinded to both the image plate and parameter setting used. The smallest detectable drill hole depth (= contrast) correctly identified was recorded for each diameter. The median values observed were calculated and tested for statistical differences between PIP and NIP using Student t test for matched pairs (level of significance P < or = 0.05). RESULTS: At all but 2 settings of the variables, NIP images depicted significantly lower contrast levels (= lower depth of drill holes) compared with PIP images. The 2 settings also showed a trend towards better low contrast depiction with NIP. In no case was low contrast performance better using PIP images. CONCLUSION: Images obtained with needle image plate/line scanner provide superior low contrast performance compared with the images obtained with powder image plate/flying-spot scanner.

Observer Variation↗

In vivo persistent pigment darkening method: a demonstration of the reproducibility of the UVA protection factors results at several testing laboratories.

BACKGROUND/PURPOSE: The aims of the present studies were to check that persistent pigment darkening (PPD) method can produce accurate and reproducible results for high UVA protection factors (UVAPF) and to provide data on the variability between laboratories and on the influence of skin types. METHODS: The Japanese Cosmetic Industry Association (JCIA) PPD method was used to determine the UVAPF in different laboratories of different sunscreen formulations with increasing UVAPF. Two formulations were tested at seven independent laboratories and five products within two laboratories. The influence of skin types on the UVAPF of two products was tested within one laboratory on two panels of volunteers. All laboratories complied with the JCIA method specifications. RESULTS: Reproducible results have been obtained between the different labs and a low and satisfactory variability was achieved with a panel size of 10 subjects. Furthermore, skin type was demonstrated to have no influence within the defined selection criteria. CONCLUSIONS: From this multiple center testing, the PPD method has been shown to be appropriate for testing sunscreen formulations with UVAPFs above 20. It is reasonable to expect that test results will be consistent if an identical protocol is used between laboratories.

Observer Variation↗

Chest radiography with a digital flat-panel detector: experimental receiver operating characteristic analysis.

PURPOSE: To evaluate the influence of different detector radiation doses and peak kilovoltage settings on diagnostic performance and radiation dose at posteroanterior (PA) chest radiography performed with an amorphous silicon flat-panel detector (FPD). MATERIALS AND METHODS: All examinations were performed by using a digital FPD. PA chest radiographs of an anthropomorphic chest phantom were obtained with detector radiation doses of 2.50 microGy (system speed, 400), 1.56 microGy (speed, 640), and 1.25 microGy (speed, 800) and with peak kilovoltage values of 100, 120, and 140 kVp. Four types of simulated lesions-nodules of different sizes, polylobulated lesions, interstitial-nodular lesions, and interstitial-reticular lesions-were superimposed on the phantom. After four radiologists assessed all of the images, receiver operating characteristics analysis was performed. In addition, the entrance surface dose was measured and the effective dose was calculated. RESULTS: Reduced detector dose led to significantly decreased diagnostic performance in overall lesion detection (P <.05). However, over pulmonary areas only, this effect could not be seen. With use of the same kilovoltage values, reducing the detector dose, even to 1.25 microGy (speed, 800), did not lead to significantly decreased lesion detectability. In terms of diagnostic performance and effective dose, 120 kVp was the most effective. CONCLUSION: Standard PA chest radiographs should still be acquired at a detector dose of 2.50 microGy (speed, 400) with 120 kVp to yield the highest diagnostic performance. However, when the present analysis was focused on the lung fields only, no significant loss in diagnostic performance could be demonstrated, even after a 50% reduction in radiation dose.

Observer Variation↗