Search PubMed⌕ Search

PubMed · 15778716

Trans-interface diffusion-controlled coarsening.

Abstract

Accurate theoretical predictions of the volume-fraction dependence during diffusion-controlled coarsening of a polydisperse assembly of particles have proved difficult. Here, a new model of coarsening is presented, involving diffusive transport through the coherent interface between ordered and disordered phases, which atomistic calculations show has a ragged structure. The interface is a diffusion bottleneck when the ordered phase is dispersed. It is predicted that the square of the average radius grows linearly with time, that the depletion of solute decreases as the inverse square-root of time, and that there is no effect of volume fraction on kinetics and the scaled particle-size distributions. These differ dramatically from predictions of modern theories of diffusion-controlled coarsening. Data on coarsening in Ni-Al alloys is examined. We show that no other theory is consistent with the experimentally observed absence of an effect of volume fraction on coarsening of ordered gamma' (Ni3Al) precipitates in a disordered Ni-Al (gamma) matrix, and the strong volume-fraction dependence of coarsening of gamma precipitates in an ordered gamma' matrix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alan J Ardell, Vidvuds Ozolins. 2005. Trans-interface diffusion-controlled coarsening.. https://doi.org/10.1038/nmat1340

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Joint properties of cast Fe-Pt magnetic alloy laser welded to gold alloys.

This study investigated the joint properties of a cast Fe-Pt magnetic alloy (Fe-36 at % Pt) laser welded to three gold alloys. The gold alloys used were ADA Type II and Type IV gold alloys, and an Ag-based (Ag-Au) gold alloy. Cast plates (0.5 x 3.0 x 10 mm) were prepared for each alloy. After the cast Fe-Pt plates were heat treated, they were butted against each of the three alloys and then laser welded with Nd:YAG laser at 200 V. Homogeneously welded specimens were also prepared for each alloy. Tensile testing was conducted at a crosshead speed of 1 mm/min. Failure load (N) and elongation (%) were recorded. After tensile testing, the fractured surfaces were examined with the use of SEM. The failure-load values of the group of alloys welded homogeneously were ranked in the order of: Ag-Au alloy > Type IV alloy > Type II alloy > Fe-Pt alloy. The Type IV alloy welded to Fe-Pt alloy had the highest failure-load value among the three alloys tested. The elongation results tended to follow a similar pattern. The results of this study indicated that Type IV gold alloy is a suitable alloy for metal frameworks to which cast Fe-Pt magnetic alloy is laser welded.

Alloys↗

Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.

Nickel-titanium shape memory alloys are promising materials in orthopedic applications because of their unique properties. However, for prolonged use in a human body, deterioration of the corrosion resistance of the materials becomes a critical issue because of the increasing possibility of deleterious ions released from the substrate to living tissues. We have investigated the use of nitrogen, acetylene, and oxygen plasma immersion ion implantation (PIII) to improve the corrosion resistance and mechanical properties of the materials. Our results reveal that the corrosion resistance and mechanical properties such as hardness and elastic modulus are significantly enhanced after surface treatment. The release of nickel is drastically reduced as compared with the untreated control. In addition, our in vitro tests show that the plasma-treated surfaces are well tolerated by osteoblasts. Among the three types of samples, the best biological effects are observed on the nitrogen PIII samples.

Alloys↗

Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.

The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. Due to excellent physical and corrosion characteristics, CoCrMo-, Ti-6Al-4V-, and Ti-6Al-7Nb-alloys are commonly used in orthopedic surgery. Yet concern has been raised with regard to the implications of inevitable corrosion product of these metals on the surrounding biologic environment, particularly in the case of CoCrMo. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to these alloys, thereby drawing conclusions on their inflammatory potential. In 28 hamsters, utilizing the dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that the implant material CoCrMo has a marked impact on local microvascular parameters. While the Ti-alloys Ti-6Al-4V and Ti-6Al-7Nb induced only a transient and moderate inflammatory response, the implantation of a CoCrMo sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity and marked leukocyte extravasation. Animals with Ti-alloys showed a clear tendency of recuperation, while in all but one CoCrMo-treated animals, a breakdown of microcirculation prior to the scheduled end of the experiment was observed. Overall, the alloy Ti-6Al-7Nb was tolerated slightly better than Ti-6Al-4V under the chosen test conditions, though this discrepancy was not statistically significant. Conclusively, the commonly used biomaterials Ti-6Al-7Nb and Ti-6Al-4V induce a considerably lower inflammatory response in the skeletal muscle microvascular system, compared to a CoCrMo-alloy. With a minimum of adverse host reaction, our results indicate that for this particular model Ti-alloys are better tolerated than CoCrMo implant materials.

Alloys↗