Search PubMed⌕ Search

PubMed · 15776218

BMD: the problem.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert P Heaney. 2005-03-18. BMD: the problem.. https://doi.org/10.1007/s00198-005-1855-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Injectable and macroporous calcium phosphate cement scaffold.

Calcium phosphate cement (CPC) can be molded and self-hardens in vivo to form resorbable hydroxyapatite with excellent osteoconductivity. The objective of this study was to develop an injectable, macroporous and strong CPC, and to investigate the effects of porogen and absorbable fibers. Water-soluble mannitol was used as porogen and mixed with CPC at mass fractions from 0% to 50%. CPC with 0-40% mannitol was fully extruded under a syringe force of 10 N. The paste with 50% mannitol required a 100-N force which extruded only 66% of the paste. At fiber volume fraction of 0-5%, the paste was completely extruded. However, at 6% and 7.5% fibers, some fibers were left in the syringe after the paste was extruded. The injectable CPC scaffold had a flexural strength (mean+/-sd; n=5) of (3.2+/-1.0) MPa, which approached the reported strengths for sintered porous hydroxyapatite implants and cancellous bone. In summary, the injectability of a ceramic scaffold, a macroporous CPC, was studies for the first time. Processing parameters were tailored to achieve high injectability, macroporosity, and strength. The injectable and strong CPC scaffold may be useful in surgical sites that are not freely accessible by open surgery or when using minimally invasive techniques.

Biomechanical Phenomena↗

A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures.

There has been a recent trend towards using a raft of small diameter 3.5mm cortical screws for supporting depressed tibial plateau fractures (Schatzker type III). Our aim was to compare the biomechanical properties of a raft of 3.5 mm cortical screws with that of 6.5 mm cancellous screws in a synthetic bone model. Ten rigid polyurethane foam (sawbone) blocks, with a density simulating osteoporotic bone and ten blocks with a density simulating normal density bone were obtained. A Schatzker type III fracture was created in each block. The fracture fragments were then elevated and supported using two 6.5 mm cancellous screws in ten blocks and four 3.5 mm cortical screws in the remaining. The fractures were loaded using a Lloyd testing machine. The mean force needed to produce a depression of 5 mm was 700.8 N with the four-screw construct and 512.4 N with the two-screw construct in the osteoporotic model. This difference was highly statistically significant (p = 0.009). The mean force required to produce the same depression was 1878.2 N with the two-screw construct and 1938.2 N with the four-screw construct in the non-osteoporotic model. Though the difference was not statistically significant (p = 0.42), an increased fragmentation of the synthetic bone fragments was noticed with the two-screw construct but not with the four-screw construct. A raft of four 3.5 mm cortical screws is biomechanically stronger than two 6.5 mm cancellous screws in resisting axial compression in osteoporotic bone.

Biomechanical Phenomena↗

Coordination of thumb joints during opposition.

Thumb opposition plays a vital role in hand function. Kinematically, thumb opposition results from composite movements from multiple joints moving in multiple directions. The purpose of this study was to examine the coordination of thumb joints during opposition tasks. A total of 15 female subjects with asymptomatic hands were studied. Three-dimensional angular kinematics of the carpometacarpal (CMC), metacarpophalangeal (MCP) and interphalangeal (IP) joints were obtained by a marker-based motion analysis system. Thumb opposition revealed coordination among joints in a specific direction (inter-joint coordination) and among different directions within a joint (intra-joint coordination). In particular, linear couplings existed between the flexion and pronation at the CMC joint, and between the flexion of the CMC joint and flexion of the MCP joint. Principal component analysis showed that only two principal components adequately represented the thumb opposition data of seven movement directions. A term functional degrees of freedom by virtue of principal component analysis was proposed to uncover the extent of movement coordination in functional tasks.

Biomechanical Phenomena↗