Search PubMed⌕ Search

PubMed · 15739395

[A new separation and extraction method--solid-phase micro-extraction].

Abstract

The principle and application of a new sample preparation method--solid-phase micro-extraction (SPME) are introduced in this paper. An SPME unit consists of a certain length of fused silica fiber coated with stationary phase, and a holder which looks like a microliter syringe. Organic analytes are adsorbed by the fiber, and is directly introduced into the GC injector, where the adsorbed analytes are desorbed. SPME can be used to concentrate volatile and nonvolatile compounds in both liquid and gaseous samples without the use of solvents and provides low detection limits. The technique is more favorable in comparing with other sample preparation methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Liu. 1997. [A new separation and extraction method--solid-phase micro-extraction].. https://pubmed.ncbi.nlm.nih.gov/15739395/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Determination of zinc in vegetable oils by FAAS with trace injection method].

A method for the determination of zinc in the soybean, cottonseed and sesame oils by FAAS with trace injection technique was discribed in this paper. The injection volume was 30 microL. The characteristic concentration and the detection limit were 0.098 and 0.00368 microg/g, respectively. The relative standard deviation was 2.6% and the recoveries were in the range of 92.9%-107.8%. The contents of zinc in the samples were 9.67, 1.42 and 1.77 microg/g, respectively.

Limit of Detection↗

[Simultaneous determination of metronidazolum and vitamin B6 by the derivative spectrophotometry].

A new method for simultaneous determination of metronidazolum and vitamin B6 was established by the third derivative spectrophotometry in 0.1 mol/L HCl solution. The detection limits were 0.81 microg/mL for metronidazolum and 0.16 microg/mL for vitamin B6. The linear range of determination was 1.6-22.4 microg/mL for both metronidazolum and vitamin B6. This method has been applied to the determination of metronidazolum and vitamin B6 in tabellae metronidazoli compositae with satisfactory results. The coefficients of variation are below 2.26 and 2.65% and the recoveries are 93-102% and 99-101% for metronidazolum and vitamin 6, respectively.

Limit of Detection↗

[Determination of 15 trace rare earth elements in rice by microwave digestion ICP-MS].

An ICP-MS method for direct determination of 15 trace rare earth elements in rice was developed. Rapid and complete dissolution of rice was achieved by a microwave digestion procedure with concentrated nitric acid and hydrogen peroxide. The detection limits are 7.0-25.8 pg/mL, the recoveries for spiked samples are 95-105%, RSDs are 2.3-4.2%. This method is rapid, sensitive and accurate.

Limit of Detection↗