Search PubMed⌕ Search

PubMed · 15733763

Modeling instructor preferences for CPR and AED competence estimation.

Abstract

INTRODUCTION: Cardiopulmonary resuscitation (CPR) and automated external defibrillator (AED) skills competency can be tested using a checklist of component skills, individually graded "pass" or "fail." Scores are typically calculated as the percentage of skills passed, but may differ from an instructor's overall subjective assessment of simulated CPR or AED adequacy. OBJECTIVE: To identify and evaluate composite measures (methods for scoring checklists) that reflect instructors' subjective assessments of CPR or AED skills performance best. METHODS: Associations between instructor assessment and lay-volunteer skill performance were made using 6380 CPR and 3313 AED skill retention tests collected in the Public Access Defibrillation Trial. Checklists included CPR skills (e.g., calling 911, administering compressions) and AED skills (e.g., positioning electrodes, shocking within 90 s of AED arrival). The instructor's subjective overall assessment (adequate/inadequate) of CPR performance (perfusion) or AED competence (effective shock) was compared to composite measures. We evaluated the traditional composite measure (assigning equal weights to individual skills) and several nontraditional composite measures (assigning variable weights). Skills performed out of sequence were further weighted from 0% (no credit) to 100% (full credit). RESULTS: Composite measures providing full credit for skills performed out of sequence and down-weighting process skills (e.g., calling 911, clearing oneself from the AED) had the strongest association with the instructor's subjective assessment; the traditional CPR composite measure had the weakest association. CONCLUSION: Our findings suggest that instructors in public CPR and AED classes may tend to down-weight process skills and to excuse step sequencing errors when evaluating CPR and AED skills subjectively for overall proficiency. Testing methods that relate classroom performance to actual performance in the field and to clinical outcomes require further research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alice Birnbaum, Mary Ann McBurnie, Judy Powell, Lois Van Ottingham, Barbara Riegel, Jerry Potts, Jerris R Hedges, PAD Investigators. 2005. Modeling instructor preferences for CPR and AED competence estimation.. https://doi.org/10.1016/j.resuscitation.2004.08.019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest.

"Bystanders" or lay persons are typically the first caregivers to attend to a victim of out-of-hospital cardiopulmonary arrest. Astronaut crew medical officers (CMO) play a similar role to bystanders aboard the International Space Station (ISS). Studies have demonstrated the importance of bystander cardiopulmonary resuscitation (BCPR) for patient survival before the arrival of emergency medical care. Recent apprehension from bystanders about the threat of contracting communicable diseases during BCPR, however, has led to the consideration of other ventilation systems such as the bag-valve mask (BVM) and automatic transport ventilators (ATV). BVM use is called for during CPR aboard the ISS. This study evaluated the ventilation and compression performance of 40 basic CPR-trained bystanders using either a BVM (adult-sized self-inflating bag with face mask) or an ATV (Model 730 ventilator (M730), Impact Instrumentation, Inc., West Caldwell, NJ). Each two-bystander team gave BCPR to a simulated cardiopulmonary arrest victim using the 2-breath/15-compression cycle for 4 min and then switched roles for another 4-min interval. Compared to BVM use, the M730 led to significantly (p<0.05) lower number of breaths, smaller tidal volumes, airway flows, airway pressures, volume of gas entering the stomach per breath and chest compressions for the 4-min period. The M730 also enabled a bystander to meet the recommendation of 4-breath and compression cycles per minute as per Guidelines 2000. Lastly, ease-of-use scores were significantly higher for the M730 compared to the BVM. Overall, the data suggest that the M730 improves the quality of performance for a bystander performing BCPR.

Cardiopulmonary Resuscitation↗