Search PubMed⌕ Search

PubMed · 15730000

Ongoing training importance stressed.

Abstract

Paul Jenkins, senior training consultant, Eastwood Park, reflects on the forces which are creating an unprecedented demand for highly specialised ongoing training in the area of decontaminating reusable surgical instruments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul Jenkins. 2005. Ongoing training importance stressed.. https://pubmed.ncbi.nlm.nih.gov/15730000/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of manufacturing process parameters on virus inactivation by dry heat treatment at 80 degrees C in factor VIII.

BACKGROUND AND OBJECTIVES: Dry heat treatment at 80 degrees C for 72 h is used as a virus inactivation step for some coagulation factor concentrates such as Bio Products Laboratory's (BPL) factor VIII 8Y. In the current study, the effect of this process has been tested on a range of viruses. In addition the effect of various manufacturing process parameters on virus inactivation has been investigated. MATERIALS AND METHODS: Samples of product intermediate were obtained from manufacturing, spiked with virus and subjected to freeze drying and dry heat treatment. Virus inactivation was determined by infectivity assay. RESULTS: Freeze drying followed by dry heat treatment was effective for inactivating a wide range of enveloped and nonenveloped viruses. Sucrose or protein concentration had no effect on virus inactivation. Product presentation or the interruption of heat treatment also had no effect. The inactivation of some of the viruses was greater at higher residual water content but under such conditions the stability of the product was reduced. CONCLUSION: This virus inactivation step was effective for a wide range of viruses and over the range of process conditions encountered in manufacturing. This demonstrates the robustness of this process step.

Decontamination↗

In vitro model for decontamination of human skin: formaldehyde.

Decontamination of a chemical from skin is often an emergency measure. This study utilized an in vitro model to compare the decontamination capacity of three model decontaminant solutions (tap water, isotonic saline, and hypertonic saline). Human cadaver skin was dosed (approximately 0.25 microg on 3 cm(2) per skin) with radio-labeled [(14)C]-formaldehyde. After a defined exposure time (1, 3, and 30 min post-dosing, respectively), the surface skin was washed three times (4ml per time) with each solution. After washing, the skin was stripped with tape discs twice. Lastly, the wash solutions, strippings, receptor fluid, and remainder of skin were liquid scintillation analyzer counted to determine the amounts of formaldehyde. Additionally, an evaporation test at different exposure times (1min, 3min, 15min, 30min, and 60min, respectively) was conducted to monitor formaldehyde % evaporation. There were no statistical differences among these groups except isotonic saline, at 3min post-exposure (in wash solutions), showed a significantly difference (p<0.05) when compared to tap water. Formaldehyde % evaporation increased linearly with extending application times, and were 7.7%, 13.6%, 19.7%, 24.4%, and 35.9% (1min, 3min, 15min, 30min, and 60min, respectively). This data suggests that isotonic saline may be effective in removing formaldehyde from skin. However, results from this model need validation in vivo. The model may provide a facile and robust method of accelerating knowledge of decontamination mechanism and lead to enhanced efficacy.

Decontamination↗

Comparative study of surgical instruments from sterile-service departments for presence of residual gram-negative endotoxin and proteinaceous deposits.

The ineffective cleaning of surgical instruments may be a vector for the transmission of hospital-acquired infections. The aim of this research was to investigate whether further decontamination procedures need to be instigated in sterile-service departments (SSDs) to reduce the risk of nosocomial illnesses, such as endotoxemia, sepsis, or iatrogenic Creutzfeldt-Jakob disease (to date, 1,147 cases of confirmed Creutzfeldt-Jakob disease deaths in the United Kingdom since 1990 have been reported). Instrument sets were obtained from nine anonymous United Kingdom National Health Service (NHS) primary care trust SSDs. The investigation implemented an advanced light microscopy technique, episcopic differential interference contrast microscopy with the sensitive fluorescent reagents SYPRO Ruby and 4',6-diamidino-2-phenylindole dihydrochloride (DAPI), to detect proteinaceous and microbial contamination levels. Gram-negative lipopolysaccharide (LPS) endotoxin was monitored using a dansylated polymyxin B fluorochrome agent. None of the 260 instruments examined displayed signs of microbial colonization or LPS endotoxin contamination. However, over 60 percent of the instruments showed a high degree of protein soiling (0.4 to 4.2 mug protein/mm(2)). Some instruments appeared soiled with crystalline deposits that may consist of a potentially hazardous material contributing to inflammation and/or surgical shock. It is clear that the overall standard for cleaning must be raised in order to fulfill the imminent introduction of new European standards and to reduce the risk of cross-patient contamination and iatrogenic transmission.

Decontamination↗