Search PubMed⌕ Search

PubMed · 15707486

An adaptive method for cDNA microarray normalization.

Abstract

BACKGROUND: Normalization is a critical step in analysis of gene expression profiles. For dual-labeled arrays, global normalization assumes that the majority of the genes on the array are non-differentially expressed between the two channels and that the number of over-expressed genes approximately equals the number of under-expressed genes. These assumptions can be inappropriate for custom arrays or arrays in which the reference RNA is very different from the experimental samples. RESULTS: We propose a mixture model based normalization method that adaptively identifies non-differentially expressed genes and thereby substantially improves normalization for dual-labeled arrays in settings where the assumptions of global normalization are problematic. The new method is evaluated using both simulated and real data. CONCLUSIONS: The new normalization method is effective for general microarray platforms when samples with very different expression profile are co-hybridized and for custom arrays where the majority of genes are likely to be differentially expressed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yingdong Zhao, Ming-Chung Li, Richard Simon. 2005-02-11. An adaptive method for cDNA microarray normalization.. https://doi.org/10.1186/1471-2105-6-28

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chemical images: technical approaches and issues.

Chemical mapping techniques using Raman microscopy are introduced, and using an example of a pharmaceutical tablet, the practical aspects of data collection and processing to produce a chemical image of the sample are detailed. Issues related to data processing, instrument standards, chemical image reportable errors, and the interpretation of chemical images are presented to encourage debate, develop solutions, and promote use in other challenging scientific applications. applications.

Calibration↗

Comparison of ELISA and capillary electrophoresis with laser-induced fluorescence detection in the analysis of Ochratoxin A in low volumes of human blood serum.

In this paper the determination of Ochratoxin A (OTA) in low volumes of human blood serum by enzyme-linked immunosorbent assay (ELISA) is compared with an appropriate capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) method. In order to use ELISA for high-throughput analysis in epidemiological studies no sample cleanup was performed. Both methods showed a limit of detection (LOD) of 0.5 ng/mL. Comparing the precisions of both methods, the data show that the quantified concentrations in ELISA are higher than the corresponding concentrations in the CE-LIF method. Using a matrix calibration curve instead of a standard calibration curve the reproducibilities of both methods are comparable. No additional matrix effect could be observed by adding phenylalanine as probable matrix compound to the serum.

Calibration↗

Analysis of metal ions in crude oil by reversed-phase high performance liquid chromatography using short column.

In this study a rapid, simultaneous analysis of V, Ni, Fe and Cu in crude oil was achieved by high performance liquid chromatography using 10 cm length reversed-phase C18 column. Since the amount of metal ions is at a very low level, in this work, solvent extraction of metals by a ligand such as 8-hydroxyquinoline from acidic media was investigated with some modification to previous procedures. Average extraction recoveries were 99, 85, 94 and 96 for V, Ni, Fe and Cu, respectively. The proposed method was successfully applied to the crude oil which was obtained from Koshk area in southern Iran. Fast analysis of metal ion in reversed-phase short column was achieved with methanol/water (55/45, v/v) and the detection limits measured as three times the background noise were obtained. Also it was shown that if small amount of 8-hydroxyquinoline was added to the mobile phase, the peak height and the peak symmetry were improved. A typical chromatogram for the separation of the 8-hydroxyquinoline complexes of V (V), Ni (II), Fe (III) and Cu (II) in crude oil was obtained in less than 4 min.

Calibration↗