Search PubMed⌕ Search

PubMed · 15656088

[Development of a new evaluation system for visual function].

Abstract

Visual deterioration is caused principally by media opacity, by retinal damage, or by disorders of the higher visual system posterior to the optic nerve. In this article, we focused on media and retinal disorders and clinically evaluated a newly developed system for visual function. The decrease in visual function in cataract is subjectively well evaluated by contrast sensitivity, but is difficult to evaluate objectively. Recently, a wavefront sensor has been developed and ocular higher-order aberration (HOA) can now be measured objectively. We studied the relationship between age and HOA by wavefront sensor and found that HOA, especially spherical aberration in the lens, increased abruptly at the presbyopic age. We also found that the against-the-rule astigmatism in the lens increased at this age. Next, we investigated monocular diplopia which was presumably caused by HOA. Nine eyes with monocular triplopia and with mild nuclear cataract showed significant increase of trefoil aberration and negative spherical aberration (p<0.001). The simulated retinal Landolt's image from these two aberrations showed a triple configuration. Thus we confirmed that triplopia is caused by the combination of trefoil aberration and negative spherical aberration in early nuclear cataract. Next, we investigated whether Area under Log Contrast Sensitivity Function (AULCSF) can be predicted by HOA and light scattering. Backward light scattering (BLS) was evaluated by Schei mpflug image and the forward light scattering (FLS) by a spot size of the Hartmann image compensated for the effect of HOA. HOA was evaluated by root mean square (RMS) value from Hartmann image in a 4 mm pupil. Multiple linear regression revealed that AULCSF could be predicted from BLS, FLS, and HOA, in which each parameter contributed to the prediction significantly (p<0.01). By using this predicted value of AULCSF, the improvement of vision after cataract surgery can be predicted in cataract complicated by retinal disease. It has been reported that by fundus camera equipped with adaptive optics (AO), which is an application of wavefront analysis, photoreceptors could be visualized 2-dimensionally. We developed a compact AO fundus camera and demonstrated that cones were separately analyzed at retinal loci 1 degree temporal to the fovea centralis when the ocular aberration was reduced to less than 0.1 microm RMS in a 6 mm pupil. We are going to use this apparatus for eyes with retinal disease. The functional evaluation of residual retinal ganglion cells (RGCs) in the retina with damage to the photoreceptors is critically important for selecting candidates for artificial retina or regenerative therapy. Transcorneal electrical stimulation (TES) of the retina via contact lens electrodes evokes phosphene and indirect pupillary reflex. The threshold current for evoking phosphene in severely degenerated retinas with visual acuity worse than counting fingers showed a wide distribution, which suggested that TES was useful to evaluate residual RGCs functionally. TES also showed a neuroprotective effect. We suggest that the activation of glial cells by TES up-regulates the production of IGF-1, which eventually protects RGCs. The peripheral retina is important for walking even though the spatial resolution is not high. We developed an apparatus to measure stereopsis in the peripheral retina using a wide screen, and evaluated the peripheral stereopsis of 12 patients after macular translocation surgery and squint surgery. All three patients who showed peripheral stereopsis had only a small amount of squint angle. This method may be useful to evaluate stereopsis in patients with a central scotoma.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Takashi Fujikado. 2004. [Development of a new evaluation system for visual function].. https://pubmed.ncbi.nlm.nih.gov/15656088/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

KLF5 promotes proliferation, migration, and autophagy-/EMT&#x2011;associated molecular changes in lens epithelial cells via transcriptional activation of THBS1 in traumatic cataract.

PURPOSE: Traumatic cataract is a common blinding eye disease after ocular trauma, and its pathogenesis is closely related to lens epithelial cell dysfunction, while the definite molecular regulatory mechanism between upstream transcription factor and downstream target gene remains poorly clarified. This study aimed to clarify the role and molecular mechanism of the kr&#xfc;ppel-like factor 5 (KLF5)/ thrombosponin 1 (THBS1) axis in regulating proliferation, migration, epithelial-mesenchymal transition and autophagy of lens epithelial cells in traumatic cataract, and to explore its potential clinical therapeutic value. METHODS: The GSE295383 dataset in the gene expression omnibus (GEO) database was downloaded, and the differentially expressed genes (DEGs) were screened by linear models for microarray data (limma) package of R language. Combined with Weighted gene co-expression network analysis (WGCNA), the gene co-expression network was constructed and the key modules were screened. Gene ontology (GO), kyoto encyclopedia of genes and genomes (KEGG) and gene set enrichment analysis (GSEA) combined with human transcription factor target (hTFtarget) and JASPAR databases were used to predict the upstream transcription factors of THBS1. Subsequently, SRA01/04 cells were induced with transforming growth factor-beta 2 (TGF-&#x3b2;2) to construct a cataract cell model. RESULTS: THBS1 and KLF5 were highly expressed in LECs exposed to TGF-&#x3b2;2. KLF5 could activate THBS1 transcription by binding to THBS1 promoter&#x2009;-&#x2009;174 to -165 sites. Knockdown of THBS1 inhibited TGF-&#x3b2;2-induced viability, proliferation, migration, and altered the expression of epithelial-mesenchymal transition (EMT)- and autophagy-related markers in LECs. Knockdown of KLF5 downregulated THBS1 expression and produced a similar inhibitory effect, while overexpression of THBS1 reversed the effect of KLF5 knockdown. CONCLUSIONS: This study demonstrated that KLF5 promoted the proliferation, migration, and EMT&#x2011;associated molecular changes of LECs in traumatic cataract through transcriptional activation of THBS1, and regulated the expression of autophagy&#x2011;related markers in LECs, suggesting that KLF5/THBS1 axis might be a potential target for the treatment of traumatic cataract.

Cataract↗

Solubility, uptake and biocompatibility of lutein and zeaxanthin delivered to cultured human retinal pigment epithelial cells in tween40 micelles.

Carotenoids lutein and zeaxanthin are proposed to protect ocular tissues from free-radical damage that can cause cataract and age-related macular degeneration (AMD). They accumulate selectively in the lens and macular region of the retina. Changes in the retinal pigment epithelium are characteristic in AMD. Efficient uptake is essential to study the intracellular effects of carotenoids in cell cultures. For in vitro experiments carotenoids are often dissolved in organic solvents like tetrahydrofuran (THF), dimethylsulfoxide (DMSO) and n-hexane, but difficulties have been associated with these application methods. Recently, O'Sullivan et al. (SM O'Sullivan et al., Br J Nutr 91 (2004) 757) developed a method whereby carotenoids could be delivered to cultured cells without the cytotoxic side effects often observed when organic solvents are used. We modified this method and investigated the effects of different carotenoid-formulations (ethanol/Tween40, methanol/tween40 and acetone/Tween40) on the uptake of lutein and zeaxanthin by differentiated ARPE-19 cells, cell viability and the expression of the "stress" gene HO-1, which is easily induced by a range of stimuli including chemical and physical agents. Micelle formulations prepared with ethanol/Tween40 resulted in the lowest LDH release, the highest carotenoid uptake and the lowest stress response (changes in HO-1 mRNA expression).

Cataract↗

Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia.

PURPOSE: To assess the accuracy of Orbscan II slit-scanning videokeratography for intraocular lens (IOL) calculation in eyes with previous photorefractive surgery for myopia. SETTING: Private practice, St. Louis, Missouri, USA. METHODS: Corneal power (K) was measured by manual keratometry, Placido-based videokeratography (Atlas), slit-scanning videokeratography (Orbscan II), and contact lens overrefraction in 21 post-photoablation eyes having cataract surgery. Postoperative data collected after phacoemulsification were used to back-calculate corneal power (BCK). The BCK values were statistically compared at 3.0 to 6.0 mm central Orbscan II curvature and power measurements, including total axial power, total tangential power, total mean power, and total optical power. Similar comparisons were made to Atlas curvature at the 0.0 to 10.0 mm zones. RESULTS: The mean corneal power after refractive surgery based on BCK values using the Holladay 2 formula (BCK H2) was 39.35 diopters (D) +/- 2.58 (SD). The mean manual value (40.52 +/- 1.95 D) and Atlas-based values were statistically higher than BCK H2 values (P<.001). The mean corneal power calculated from historical data was 39.33 +/- 2.70 D (P = .83 to BCK H2; n = 19) and from contact lens overrefraction, 41.38 +/- 3.11 D (P = .19; n = 5). Orbscan II parameters (n = 21) of the total mean power (3.0 mm, 39.10 +/- 2.63 D), total tangential power (3.0 mm, 39.11 +/- 2.60), total axial power (5.0 mm, 39.19 +/- 2.55 D), and total optical power (3.0 mm, 39.08 +/- 2.78 D; 4.0 mm, 39.39 +/- 2.76 D) were statistically similar to both the historical and BCK H2 values (P>.11). If used prospectively, 80.9% of eyes would have been within +/-0.50 D of the targeted refraction using a 4.0 mm total optical power, 76.2% using a 5.0 mm total axial power, and 42.1% using the historical method. CONCLUSION: The Orbscan II 5.0 mm total axial power and 4.0 mm total optical power can be used to more accurately predict true corneal power than the history-based method and may be particularly useful when pre-LASIK data are unavailable.

Cataract↗