Search PubMed⌕ Search

PubMed · 15650609

A trabecular bypass flow hypothesis.

Abstract

PURPOSE: To introduce a hypothesis that theorizes the effect of a trabecular bypass, a channel created through the trabecular meshwork, on the facility of outflow and the intraocular pressure (IOP). METHODS: Equations that govern the pressure and circumferential flow in Schlemm's canal are established, based on the linear relationships between pressure drop and flow, the balance of flows in the canal, and a uniform leaking structure of collector channels. Two types of bypasses permitting either unidirectional or bidirectional flow are incorporated through boundary conditions to solve the equations and to derive the facility of outflow and the reduced IOP. RESULTS: In normal healthy eyes, the facility of outflow increases by 13% and 26% in the presence of a unidirectional and bidirectional bypass, respectively. The circumferential flow is significant only in the immediate quadrant to the bypass. The elevated IOP due to the abnormally high resistance in trabecular meshwork in open angle glaucoma is substantially reduced with a single bypass. Mean physiological level of IOP is attained if the bidirectional bypass is placed; slightly higher IOP is attained if a unidirectional bypass is placed. In either case, the higher the baseline IOP, the greater the reduction. The effectiveness of the bypass on IOP reduction is related to the resistances in the canal and the collector channels. Multiple bypasses can be used to further reduce the IOP. CONCLUSION: It is theoretically demonstrated that a single patent trabecular bypass can enhance the facility of outflow and reduce the IOP to physiological levels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jianbo Zhou, Gregory T Smedley. 2005. A trabecular bypass flow hypothesis.. https://doi.org/10.1097/01.ijg.0000146360.07540.ml

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.

PURPOSE: To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. MATERIALS AND METHODS: A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. RESULTS: The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). CONCLUSIONS: The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.

Aqueous Humor↗

Myocilin-associated exosomes in human ocular samples.

Mutations in myocilin result in ocular hypertension, likely due to decreased drainage of aqueous humor through the trabecular meshwork. Since less myocilin is found in the aqueous humor of those with disease-causing mutations, understanding myocilin's role in the aqueous humor is of clinical importance. Recently, myocilin was shown to exit cultured trabecular meshwork cells in association with shed vesicles called exosomes. To examine relevance of this finding in a physiological setting, the present study examined three different types of ocular samples for the presence of myocilin-associated exosomes. Using differential centrifugation steps, we found myocilin associated with exosomes isolated from effluent collected from human anterior segments in organ culture and aqueous humor obtained from human cadaveric eyes or from patients undergoing excisional surgery. Similar to results with cultured cells, myocilin associated predominately with exosomes in fresh samples, appeared mostly soluble at later times, and had biochemical properties (density of 1.13-1.19 g/ml in linear sucrose gradient) similar to those characteristics of exosomes. These data indicate that exosomes are present and may facilitate the transport of myocilin into the extracellular space of human ocular cells.

Aqueous Humor↗