Search PubMed⌕ Search

PubMed · 1564951

Sampling fluid from slice chambers by microsiphoning.

Abstract

We have developed a simple technique that continuously samples perfusion fluid from an in vitro slice chamber and permits simultaneous electrophysiological recordings from a slice. This procedure uses a microsiphon that diverts approximately 1.5% of the total effluent of artificial cerebrospinal fluid from an interface slice chamber into a collection tube at a lower level outside the chamber. The tip of the microsiphon may be moved anywhere within the chamber without disturbing the slice. For optimum sampling of the release of substances from one area of a slice, the tip is positioned immediately downstream from the location being studied. Concentrations of several amino acids were measured to identify significant spatial and temporal characteristics of the technique and to demonstrate that spontaneous and induced release of amino acids from slices can be measured with adequate sensitivity and time resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Godfrey, H J Waller. 1992. Sampling fluid from slice chambers by microsiphoning.. https://doi.org/10.1016/0165-0270(92)90058-l

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chimeric structural isomer fragments as cost-efficient internal standards for amino acid quantification by mass spectrometry.

Amino acid (AA) profiles from body fluids such as blood and urine are clinical indicators for diagnosing metabolic and hepatic diseases. Current quantitative methods, such as liquid chromatography-mass spectrometry (LC-MS) with isotopically labelled internal standards (ISs), are costly and technically demanding. This study proposes a cost-efficient alternative using structural isomers as ISs in a direct liquid infusion (DLI) tandem mass spectrometry (MS/MS) approach. The method leverages chimeric spectra and fragment intensity ratios to quantify AAs, demonstrating high linearity and precision even with a 3D ion trap mass analyser. This approach offers a viable strategy for AA quantification in preventive medicine, particularly for screening metabolic diseases such as phenylketonuria, diabetes, and liver dysfunction.

Amino Acids↗

Design, docking, and evaluation of multiple libraries against multiple targets.

We present a general approach to the design, docking, and virtual screening of multiple combinatorial libraries against a family of proteins. The method consists of three main stages: docking the scaffold, selecting the best substituents at each site of diversity, and comparing the resultant molecules within and between the libraries. The core "divide-and-conquer" algorithm for side-chain selection, developed from an earlier version (Sun et al., J Comp Aided Mol Design 1998;12:597-604), provides a way to explore large lists of substituents with linear rather than combinatorial time dependence. We have applied our method to three combinatorial libraries and three serine proteases: trypsin, chymotrypsin, and elastase. We show that the scaffold docking procedure, in conjunction with a novel vector-based orientation filter, reproduces crystallographic binding modes. In addition, the free-energy-based scoring procedure (Zou et al., J Am Chem Soc 1999;121:8033-8043) is able to reproduce experimental binding data for P1 mutants of macromolecular protease inhibitors. Finally, we show that our method discriminates between a peptide library and virtual libraries built on benzodiazepine and tetrahydroisoquinolinone scaffolds. Implications of the docking results for library design are explored.

Amino Acids↗

Sequence codes for extended conformation: a neighbor-dependent sequence analysis of loops in proteins.

We performed an extensive sequence analysis on the loops of proteins. By dividing a loop databank derived from the Protein Data Bank into groups, we analyzed the chemical characteristics and the sequence preferences of loops of different lengths and loops connecting different secondary structures in proteins. We found that a large population of loops in our loop databank (94.4%) is either partially or completely surface-exposed. A majority of surface loops in proteins are hydrophilic, whereas the chemical characteristics of interior loops are relatively neutral according to Eisenberg's consensus hydrophobicity scale. As a first step in investigating the intrinsic sequence-structure relationship of loop sequences in proteins, we performed a neighbor-dependent sequence analysis that calculated the effect of the neighboring amino acid type on the loop propensity of residues in loops. This method enhances the statistical significance of residue propensity, thus allowing us to explore the positional preference of amino acids in loops. Our analysis yielded a series of amino acid dyads that showed high preference for loop conformation. The data presented in this study should prove useful for developing potential codes in recognizing loop sequences in proteins.

Amino Acids↗