Decrease in haematocrit with continuous positive airway pressure treatment in obstructive sleep apnoea patients.

Abstract

Previous preliminary results have shown an overnight decrease in haematocrit and red cell count after the first night of treatment with nasal continuous positive airway pressure (CPAP) in obstructive sleep apnoea (OSA) patients. The present study was designed to confirm these preliminary data, and to analyse the long-term effects of CPAP. The haematocrit and red cell count (RCC) were measured in 80 OSA patients on two consecutive mornings, after an untreated night and after a CPAP treatment night. The haematocrit and RCC significantly decreased with CPAP (from 44.0 +/- 0.5 to 42.4 +/- 0.4%, p less than 0.0001 and from 4.769 +/- 0.051 to 4.597 +/- 0.052 x 10(12) red cells.l-1, p less than 0.0001, respectively). Neither the decrease in haematocrit nor the decrease in RCC were correlated with the decrease in urine volume or flow which occurred with CPAP. Thirty five of these patients remained untreated for 45 +/- 4 days, before home treatment with CPAP was initiated. The haematocrit and RCC had returned to values close to those before initial treatment and decreased again after the first treatment night. Twenty one of the patients were re-evaluated after at least one year of home treatment with CPAP, again on two consecutive nights either with CPAP or untreated. The follow-up, post-CPAP haematocrit and RCC were slightly and nonsignificantly higher than after the baseline CPAP night, but still lower than after the baseline untreated night (p less than 0.02). After the untreated follow-up night, no significant change in haematocrit was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Krieger, E Sforza, C Delanoe, C Petiau. 1992. Decrease in haematocrit with continuous positive airway pressure treatment in obstructive sleep apnoea patients.. https://pubmed.ncbi.nlm.nih.gov/1559588/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of plateletpheresis using Cobe Spectra System and Fresenius AS 104.

To evaluate separation efficiency and concentrate purity, each of 50 donors underwent platelet (PLT) collection on both the Cobe Spectra and Fresenius AS 104 with the constancy of processed blood volume, ACD/blood ratio 1:10 and a blood flow of 50 ml/min. For the Fresenius AS 104 two protocols - V 4.11 and V 4.4 - were evaluated. Both systems provided high quality PLT collection: PLT yield 3.91 +/- 0.74 x 10(11) (Cobe); 4.16 +/- 1.12 x 10(11) (V 4.11); 4.66 +/- 0.89 x 10(11) (V 4.4). The mean cell contamination was low with all procedures, resulting in less WBC contamination with the Fresenius AS 104, whereby the higher efficiency obtained by the protocol version V 4.4 correlated with an increased of WBC contamination.

Erythrocyte Count

The basics of blood cell counter.

The time has come when a traditional hematologist of a developing country needs to change his frame of mind from time consuming, error prone, not so precise manual methodologies to economical, safe and precise automated procedures. More important is his role as a guide and teacher for his juniors who are exposed to automated laboratories from the beginning of their residency. At this juncture, one needs to be thorough with the principles of instrumentation, different models available, their merits and demerits and how and where these fit with the requirements of the laboratory. The haematologists also must be aware that automation has its own problems, limitations, disadvantages and interfering elements. The article discusses the present state of art.

Erythrocyte Count

Fetal red cell staining: method evaluation.

Acid elution methods have been extensively used for the identification of fetal red cells in pregnant women with fetomaternal hemorrhage. A number of methods have been described: Kleihauer-Betke, Boehringer Mannheim, Fetaldex, Nierhaus-Betke modification and Sanguansermsri amido black B. A comparative evaluation of these methods was performed in this study. The technique of Sanguansermsri using amido black B was found to be more advantageous than the others in terms of simplicity, accuracy, precision and time taken.

Erythrocyte Count