Search PubMed⌕ Search

PubMed · 15587642

[EDTA again].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erik Højstrup Christensen. 2004-11-22. [EDTA again].. https://pubmed.ncbi.nlm.nih.gov/15587642/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Metal speciation in sulphidic sediments: a new method based on oxidation kinetics modelling in the presence of EDTA.

The solid phase partitioning of metals (Zn, Cu and Pb) was determined in four anoxic, metal polluted sediments by investigating at pH 8 the 1 day oxidation kinetics of the metal sulphide phases present in the sediments in a background solution containing excess EDTA. A mathematical model consisting of a combination of two pseudo-first order reactions was used to fit the metal release data as a function of oxidation time. The model permitted to fractionate the trace metals in a 'quickly-oxidizable' and a 'slowly-oxidizable' fraction, which could be assigned to two different trace metal pools, respectively (1) FeS minerals (e.g. amorphous FeS, mackinawite) and (2) discrete trace metal sulphide phases. The sum of the fractions associated with these sulphide pools was taken as an approximation for the sulphide-associated fraction of the trace metals and coincided (for the case of Zn and Pb) with the sulphide-associated fraction derived from the analysis of acid volatile sulphide (AVS) and simultaneously extracted metals (SEM). Oxidation kinetics modelling allowed also determining the sulphide-associated fraction of a broad range of trace metals (as demonstrated for Cu) more accurately than the AVS/SEM method, which suffers from non-efficient extraction of a number of trace metal sulphides. A correction was made for the determination of the sulphide-associated fraction by subtracting the trace metal fraction dissolved after 1 day under anoxic conditions in the background EDTA solution. The combination of (1) one day oxidation kinetics modelling and (2) correction for the 1 day anoxic EDTA-soluble fraction is a suitable method to determine accurately the true sulphide speciation of trace metals in anoxic sediments.

Edetic Acid↗

UV and fluorescence spectral changes induced by neodymium binding of N,N'-ethylenebis[2-(o-hydroxyphenolic)glycine] and N,N'-di(2-hydroxybenzyl)ethylenediamine-N,N' diacetic acid.

In 0.01 M 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (Hepes), pH 7.4 and room temperature, the binding of neodymium to N,N'-ethylenebis[2-(o-hydroxyphenolic)glycine] (EHPG), or N,N'-di(2-hydroxybenzyl)ethylenediamine-N,N' diacetic acid (HBED) had been studied from 210 to 330 nm by means of difference UV spectra. Two peaks at 240 and 292 nm appear in difference UV spectra after neodymium binding to EHPG or HBED. The 1:1 stable complex can be confirmed from spectral titration curves. The molar extinction coefficient of Nd-EHPG and Nd-HBED complexes are Deltaepsilon(Nd-EHPG)=(12.93+/-0.21) x 10(3)cm(-1)M(-1), Deltaepsilon(Nd-HBED)=(14.45+/-0.51) x 10(5)cm(-1)M(-1) at 240 nm, respectively. Using EDTA as a competitor, the conditional equilibrium constants of the complexes are logK(Nd-EHPG)=11.89+/-0.09 and logK(Nd-HBED)=12.19+/-0.15, respectively. At the same conditions, fluorescence measurements show that neodymium binding to EHPG leads to a quenching of the fluorescence of EHPG at near 310 nm. However, there is no obvious fluorescence change of HBED at 318 nm with the binding of neodymium to HBED.

Edetic Acid↗

Fluorescence studies of ternary complexes of Europium and Terbium and their application to analytical determinations.

Europium and Terbium were found to form ternary complexes with ethylenediammine tetraacetic acid (EDTA) and ortho-phenanthroline (o-phen) in aqueous solution in the pH range of 6-8. These ternary complexes were found to have 1:1:1 composition and showed strong fluorescence properties. The method is made use of for the determination of these lanthanide ions in presence of excess amounts of other lanthanide ions. The lowest detection limit was calculated as 30 and 65 ng/ml of Tb(3+) and Eu(3+), respectively.

Edetic Acid↗