[Digital fluorograph with automatic exposition].

Abstract

Discussed in the paper is a system of automatic exposition choice in a digital fluorograph designed by the "Gelpik" company, Moscow. The perspective equipment variation is as follows: intensifying screen + optic system + charge-communication device-matrix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A B Mishkinis, B M Kanter. [Digital fluorograph with automatic exposition].. https://pubmed.ncbi.nlm.nih.gov/15568514/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patient and staff dosimetry in vertebroplasty.

STUDY DESIGN: Eleven vertebroplasty operations were studied in terms of radiation dose. OBJECTIVE: Doses to patients and staff associated with vertebroplasty were measured. Occupational doses were compared with the annual dose limits, and the effectiveness of the used radiation protection means was estimated. Patient dose was estimated by means of both surface and effective dose, and the radiation-induced risk was evaluated. SUMMARY OF BACKGROUND DATA: Vertebroplasty is a recent minimally invasive technique for the restoration of vertebral body fractures. It involves fluoroscopic exposure, and so, it demands dose measurements for both patient and staff exposed to radiation. METHODS: Thermoluminescent dosimeters (TLDs) were placed on the medical personnel and the effective dose was derived. Slow films were placed to patients' skin to measure entrance surface dose. Furthermore, a Rando phantom loaded with TLDs was irradiated under conditions simulating vertebroplasty, in order to estimate effective dose to the patient. RESULTS: Mean fluoroscopy time was 27.7 minutes. Patient's mean skin dose was 688 mGy, while effective dose was calculated to be 34.45 mGy. It was estimated that the primary operator can perform about 150 vertebroplasty operations annually without exceeding the annual dose constraints, whereas occupational dose can be reduced by 76% using mobile shielding. CONCLUSIONS: Measures have to be taken to reduce patient's skin dose, which, in extreme cases, may be close to deterministic effects threshold. The highest dose rates, recorded during the procedure, were found for primary operator's hands and chest when no shielding was used.

Fluoroscopy↗

An inter-hospital comparison of patient dose based on clinical indications.

Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 microSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals.

Fluoroscopy↗

[Navigation surgery and fracture treatment].

During operative fracture treatment the surgeon depends on fluoroscopic or X-ray radiological images as well as CT scans or MRI scans. This means that the surgeon sees only images at a given moment. Continuous imaging is technically complex and is accompanied by considerable exposure to radiation. Between images the surgeon has to depend on his or her knowledge of anatomical relationships and three-dimensional orientation. This may lead to the incorrect positioning of implants with ensuing morbidity and sometimes even death. Throughout the surgical procedure, computer assisted surgery (CAS) informs the surgeon of the exact position of the instruments in relation to the affected bone. The concept can be compared to that of the global positioning system (GPS) that is used by motorists. Clinical applications of CAS have been described for the operative treatment of vertebral fractures as well as fractures of the pelvis, hip and long bones. In reconstructive surgery, CAS is used for positioning the patient for total hip and knee surgery. The potential advantages of CAS are: increased accuracy, safety and reproducibility combined with lower radiation levels. Currently CAS is not widely used. There are a number of reasons for this. The technique is expensive and complex although the newer systems are more user friendly. It is possible that in the future CAS will be in standard use in orthopaedic and trauma surgery.

Fluoroscopy↗