Abstract

The goal of this study is to develop a monitoring system for activated sludge properties, as this is an essential tool in the battle against filamentous bulking. A fully automatic image analysis procedure for recognising and characterising flocs and filaments in activated sludge images has been optimised and subsequently used to monitor activated sludge properties in a lab-scale installation. The results of two experiments indicate that the image information correlates well with the Sludge Volume Index. It is shown that, at the onset of filamentous bulking, there is an increase in total filament length on the one hand, and a change in floc shape on the other hand.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Jenné, E N Banadda, I Y Smets, J F Van Impe. 2004. Monitoring activated sludge settling properties using image analysis.. https://pubmed.ncbi.nlm.nih.gov/15553487/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Blood component collection by apheresis.

Apheresis component collection is a rapidly growing area in the blood collection field. Several instruments with varying capabilities are available. This is a brief review of the equipment available for granulocyte and apheresis component collection and indications for their use. In the United States, granulocytes are collected with the Fenwal CS3000, Fenwal CS3000 Plus, COBE (Gambro) Spectra, Haemonetics LN9000, and Fresenius AS 104. The use of hetastarch for sedimenting agent and stimulation with G-CSF and G-CSF plus dexamethasone have substantially increased granulocyte yields. Plateletapheresis is performed in the United States on the Fenwal CS3000, Fenwal CS3000 Plus, Fenwal Amicus, COBE (Gambro) Spectra, Gambro Trima Version 4, Gambro Trima Accel (Version 5), and Haemonetics LN9000. Automated red blood cell (RBC) collections are performed with the Haemonetics MCS+LN8150, Gambro Trima Version 4, Gambro Trima Accel (Version 5), Amicus, and Baxter Alyx. The RBC can be collected concurrently (with other components) in some instruments or separately in others. Plasma is collected concurrently on several instruments. Plasmapheresis for plasma only is performed on the Fenwal Autopheresis C and Haemonetics PCS2. Granulocyte yields range from 0.46 x 10(10) to 1.0 x 10(10) for unstimulated donors and 2.1 x 10(10) to 2.6 x 10(10) for donors stimulated with dexamethasone or prednisone. The use of G-CSF and G-CSF with dexamethasone has substantially increased granulocyte yields with yields of 4.1 x 10(10) to 10.8 x 10(10) reported. Platelet collection rates of 0.045-0.115 x 10(11) plt/min have been reported. Collection efficiencies of 46-85.7% have been reported. Automated (apheresis) component collection has the advantages of controlled volumes or doses of component, efficient use of the donor, multiple components from the same donor, better inventory control, and better quality control due to less manipulation of the individual components. Disadvantages of automated component collection include the use of expensive equipment and disposables, the need for specially trained machine operators, and lower capacity to collect large volumes of blood compared to whole blood donation. The use of apheresis component collection is rapidly growing to provide the best blood components in the most efficient manner.

Automation↗

Fully automated liquid-liquid extraction for the determination of a novel insulin sensitizer in human plasma by heated nebulizer and turbo ionspray liquid chromatography-tandem mass spectrometry.

I, 2-{[5,7-dipropyl-3-(trifluoromethyl)-1,2-benzisoxazol-6-yl]oxy}-2-methyl propionic acid is an alpha peroxisome proliferator-activated receptor (PPAR) agonist with some gamma activity being investigated for potential use in the treatment of Type II diabetes mellitus and dyslipidemia. Two automated liquid-liquid extraction methods were developed and validated for the determination of I in human plasma. Concentrations of I were determined over a wide range of clinical doses. For Method A, plasma was acidified and extracted with ethyl acetate using a fully automated procedure. Analysis was performed by LC-MS/MS with a turbo ionspray source in negative ion mode. For Method B, a larger volume of plasma was extracted and a heated nebulizer source was used on the mass spectrometer. Method A was linear from 0.05 to 50 ng/mL and Method B from 0.2 to 1000 ng/mL. Validation procedures showed that both methods were robust, specific and reproducible.

Automation↗

Automated computation of low-energy pathways for complex rearrangements in proteins: application to the conformational switch of Ras p21.

The computation of minimum energy paths (MEPs) is an approach for gaining insight into protein conformational transitions that are too slow to be observed with unconstrained molecular dynamics simulations. MEPs have the advantage of providing the energy barrier of the rate-limiting step(s), allowing discrimination among different paths. Finding low-energy MEPs for complex transitions, such as those involving rearrangements of the backbone fold or repacking of buried side chains, has hitherto been unfeasible in a reliable, automated manner, the MEP often displaying unphysical behavior, such as the crossing of bonds. Here, this problem is addressed by combining a counterintuitive procedure for generating an initial guess of the path, in which all side chains are shrunk, with the conjugate peak refinement (CPR) method. The effectiveness of the approach is tested on the conformational switch in Ras p21. This conformational transition involves some partial unfolding and re-folding, a process for which a multitude of pathways are likely to exist and for which a single MEP does not provide a complete description. However, this transition requires some sterically demanding rearrangements, thus testing the ability of a method to find low-energy pathways free of structurally unphysical events. This is achieved by the present approach, which finds a path whose rate-limiting barrier is compatible with experiment. This demonstrates that the method can be used to compute plausible pathways for complex rearrangements in proteins in an automated manner that is unbiased by external driving constraints.

Automation↗