Search PubMed⌕ Search

PubMed · 15536539

Physical training and hormone replacement therapy reduce the decrease in bone mineral density in perimenopausal women: a pilot study.

Abstract

The effects of physical training and hormone replacement therapy (HRT) on bone mineral density in perimenopausal women were studied. Sixty perimenopausal women were randomized to either physical training (n = 20), HRT (n = 20), or control group (n = 20). The study period was 18 months. Bone mineral density (BMD) in the femoral neck and lumbar spine was measured using dual-energy X-ray absorptiometry (DXA). DXA was performed before treatment and after 6 and 18 months. Blood samples for analysis of the bone markers U-deoxypyridinoline and osteocalcin were collected at the same time points. After 18 months, BMD in the spine had not decreased in either the training group or in the HRT group. In the control group, spine BMD had significantly decreased (p = 0.0014). U-Deoxypyridinoline and osteocalcin were increased significantly in the control group (p = 0.0198, p = 0.0295, respectively). No significant changes in bone marker levels were found in the training group or the HRT group. We found that both HRT and physical training can prevent loss of spine BMD in perimenopausal women over a period of 18 months. HRT remains a cornerstone in the treatment of vasomotor symptoms and preservation of BMD. However, HRT can only be used for limited periods of time due to the potential serious adverse effects. This study indicates a beneficial effect of physical activity on spine BMD in the perimenopausal period, and highlights its potential as an alternative to HRT during this period.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ingrid Bergström, Bo Freyschuss, Britt-Marie Landgren. 2004-11-05. Physical training and hormone replacement therapy reduce the decrease in bone mineral density in perimenopausal women: a pilot study.. https://doi.org/10.1007/s00198-004-1758-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple non invasive computerized method for the assessment of bone repair within osteoconductive porous bioceramic grafts.

Single energy X-ray imaging, due to its low cost and flexibility, is one of the most used and common technique to assess bone state and bone remodeling over time. Standardized X-ray images are needed to compare sets of radiographs for semi-quantitative analyses of tissue remodeling. However, useful mathematical modeling for the analysis of high level radiographic images are not easily available. In order to propose a useful evaluation tool to a wide clinical scenario, we present an innovative calibration algorithm for a semi-quantitative analysis of non-standardized digitized X-ray images. For calibration on a unique standardization scale, three time invariant regions (ROI) of radiographs were selected and analyzed. The accuracy of the normalization method for X-ray films was successfully validated by using an aluminum step wedge for routine X-ray exposures as tool to standardize serial radiographs (Pearson correlation test: R(2) = 0.96). This method was applied to investigate the progression of the new bone deposition within ceramic scaffolds used as osteoconductive substitute in large bone defects taking advantage of a large animal model. This innovative image-processing algorithm allowed the identification and semi-quantification of the bone matrix deposited within the implant. The osteo-integration at the bone-implant interface was also investigated. A progressively increasing bone tissue deposition within the porous bioceramic implant and a progressive osteo-integration was observed during the 12 months of the trial.

Absorptiometry, Photon↗

Combined LIBD and XAFS investigation of the formation and structure of Zr(IV) colloids.

The solubility of Zr(OH)4(am)--in other words hydrated Zr(IV) oxyhydroxide--is determined by means of coulometric titration (CT), and colloids are detected by laser-induced breakdown when the solubility limit is exceeded. Our results at pH 3-8 demonstrate that the solubility of Zr(OH)4(am) is several orders of magnitude higher than reported classical solubility data for acidic solutions, determined from undersaturation with a less soluble microcrystalline Zr(IV) oxide precipitate. Analysis of extended X-ray absorption fine structure (EXAFS) data shows that the microcrystalline colloids in a 0.1 mol l(-1) Zr aqueous solution at pH 0.2 contain tetrameric units, similar to those present in the structure of ZrOCl2.8H2O. Characterization of the CT solutions by means of EXAFS shows that oligomeric species form as the solubility limit is approached. The current lack of data on equilibrium constants for polynuclear hydroxide complexes prohibits the use of a realistic speciation model to describe the solubility of pH-dependent Zr(OH)4(am). However, the solubility curve is obtained using the mononuclear hydrolysis constants estimated in the present paper, along with the solubility constant (log K'sp=-49.9+/-0.5 in 0.5 mol l(-1) NaCl; log K degrees(sp)=-53.1+/-0.5 at I=0).

Absorptiometry, Photon↗

Three-dimensional modeling of EXAFS spectral mixtures by combining Monte Carlo simulations and target transformation factor analysis.

We have developed a new method for the three-dimensional modeling of extended X-ray absorption fine structure (EXAFS) spectra which enables the extraction of the local structure of aqueous metal complexes from spectral mixtures of several components. The new method combines two techniques: Monte Carlo simulation and target transformation factor analysis (TFA). Monte Carlo simulation is used to create random arrangements between the X-ray absorbing metal ion and the ligand atoms, and to calculate the theoretical EXAFS spectrum of each arrangement. The theoretical EXAFS spectrum is then introduced as test spectrum in the TFA procedure, to test whether or not the test spectrum is likely to be a component of the spectral mixtures. This coupled procedure is repeated until the error in the test spectrum is minimized. The new method can thus be used to isolate and refine the structure of complexes from spectral mixtures and to determine their relative concentrations, solely on the basis of an estimate of a ligand structure. The performance of the proposed method is validated using uranium Liii-edge EXAFS spectra of binary mixtures of two uranium(VI) 3,4-dihydroxybenzoic acid complexes.

Absorptiometry, Photon↗