Safer design of process equipment can protect against unexpected events. Two case studies involving the design of a process vessel and the subsequent events will be reviewed. One case study will show how the original design minimized equipment damage from an operational error, and how additional safeguards will prevent recurrence. The second case study will show that over time small process changes can lead to an unexpected chemical reaction that results in a vessel rupture. We will also cover the additional safeguards added to prevent recurrence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rande H Grotefendt, J Wayne Chastain. 2004-11-11. Learning from what went wrong--two case studies.. https://doi.org/10.1016/j.jhazmat.2004.05.005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimentally validated 3-D simulation of shock waves generated by dense explosives in confined complex geometries.

Accidental blast wave generation and propagation in the surroundings poses severe threats for people and property. The prediction of overpressure maxima and its change with time at specified distances can lead to useful conclusions in quantitative risk analysis applications. In this paper, the use of a computational fluid dynamics (CFD) code CFX-5.6 on dense explosive detonation events is described. The work deals with the three-dimensional simulation of overpressure wave propagation generated by the detonation of a dense explosive within a small-scale branched tunnel. It also aids at validating the code against published experimental data as well as to study the way that the resulting shock wave propagates in a confined space configuration. Predicted overpressure histories were plotted and compared versus experimental measurements showing a reasonably good agreement. Overpressure maxima and corresponding times were found close to the measured ones confirming that CFDs may constitute a useful tool in explosion hazard assessment procedures. Moreover, it was found that blast wave propagates preserving supersonic speed along the tunnel accompanied by high overpressure levels, and indicating that space confinement favors the formation and maintenance of a shock rather than a weak pressure wave.

Chemical Industry↗

The historic and current use of glycol ethers: a picture of change.

The use of glycol ethers has changed significantly over the past 30 years. Low molecular weight E-series have been phased-out and progressively replaced by low molecular weight P-series whenever possible. There is a trend to shift from E-series to P-series and an obvious willingness to substitute where alternative solutions exist or as a consequence of strengthening regulation and voluntary measures to reduce exposure in the workplace.

Chemical Industry↗