This is a mainly historical account of the events, methods and artifacts arising from my collaboration with Adam Curtis over the past twenty years to make exercise grounds for biological cells. Initially the structures were made in fused silica by photo-lithography and dry etching. The need to make micron-sized features in biodegradable polymers, led to the development of embossing techniques. Some cells response to grooves only a few tens of nanometers deep--this led to a desire to find the response of cells to features of nanometric size overall. Regular arrays of such features were made using electron beam lithography for definition of the pattern. Improvements were made in the lithographic techniques to allow arrays to be defined over areas bigger than 1 cm2. Structures with microelectrodes arranged inside guiding grooves to allow the formation of sparse predetermined networks of neurons were made. It is concluded that the creation of pattern, as in vivo, in assemblies of regrown cells in scaffolds may well be necessary in advanced cell engineering applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C D W Wilkinson. 2004-10-22. Making structures for cell engineering.. https://doi.org/10.22203/ecm.v008a03

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biocompatibility of titanium implants modified by microarc oxidation and hydroxyapatite coating.

A thin hydroxyapatite (HA) layer was coated on a microarc oxidized titanium (MAO-Ti) substrate by means of the sol-gel method. The microarc oxidation (anodizing) enhanced the biocompatibility of the Ti, and the bioactivity was improved further by the sol-gel HA coating on the anodized Ti. The HA sol was aged fully to obtain a stable and phase-pure HA, and the sol concentration was varied to alter the coating thickness. Through the sol-gel HA coating, the Ca and P concentrations in the coating layer increased significantly. However, the porous morphology and roughness of the MAO-Ti was altered very little by the sol-gel treatment. The proliferation and alkaline phosphatase (ALP) activity of the osteoblast-like cells on the MAO/HA sol-gel-treated Ti were significantly higher than those on the MAO-Ti without the HA sol-gel treatment.

Absorbable Implants↗

Physical characteristics of small intestinal submucosa scaffolds are location-dependent.

Using biodegradable scaffolds as an alternative to engineer new tissues has become an attractive candidate in various transplantation protocols. In particular, small intestinal submucosa (SIS), a dense connective matrix harvested from the small intestine, has gained attention due to a number of favorable properties. However, use of SIS is constrained by obtaining reliable, reproducible products in large-scale preparations that affect the regenerative process. To better understand the heterogeneous nature of SIS, this study focused on evaluating the location-dependent alterations in the physical characteristics of the matrices harvested from distal and proximal ends and processed in-house (referred as hand-made). Additionally, results were compared with a commercially available machine-made Cook SIS. Tensile properties during monotonic loading and cyclical loading were compared in wet conditions. Furthermore, permeability of these membranes to urea was analyzed using a custom-built chamber, and the microarchitecture was analyzed via scanning electron microscopy. These results showed that distal samples were more elastic and less permeable to urea relative to other samples. However, permeability in each sample was direction-dependent, that is, mucosal to serosal direction was less permeable compared to sorasal to mucosal direction in all the samples. Cook SIS was more susceptible to cyclical loading and had a shorter range of load carrying capacity. In summary, results show that physical characteristics of SIS are location-dependent.

Absorbable Implants↗

Effect of varied release kinetics of the osteogenic thrombin peptide TP508 from biodegradable, polymeric scaffolds on bone formation in vivo.

This study was designed to assess the influence of varied release kinetics of the osteogenic thrombin peptide TP508 from osteoconductive poly(propylene fumarate)-based (PPF) composite scaffolds on bone formation in vivo. Four classes of scaffolds were constructed with different TP508 dosages (200, 100, or 0 microg) and release kinetics (large burst release, minimal burst release, or no release) and implanted in 15.0 mm segmental defects in rabbit radii. The animals were euthanized at 12 weeks and the implants were analyzed by light microscopy, histological scoring analysis, and histomorphometric analysis. Samples from all classes displayed bone growth within the pores of the scaffold near the edges of the defect. In areas where bone was not observed, the pores were filled with mostly fibrous tissue and exhibited minimal inflammatory response for all classes. In contrast to other scaffold classes, scaffolds containing a total dose of 200 microg TP508 and exhibiting a large burst release profile showed statistically more bone formation guided along the surface of the scaffold, with these scaffolds averaging 80% of the defect length bridged with bone compared to 10% or less bridged for the other scaffold classes. These results demonstrate that the extent of in vivo bone formation in response to controlled release from PPF-composite scaffolds is determined by the release kinetics of the incorporated osteogenic peptide.

Absorbable Implants↗