Search PubMed⌕ Search

PubMed · 15464596

A diffusion-reaction model for DNA microarray assays.

Abstract

DNA microarrays are extensively used for the quantification of the degree of differential mRNA expression. The assay involves hybridization of mobile DNA strands with immobilized complementary DNA strands to form duplexes. The overall duplex formation rate depends on the rate of transport of strands in solution to the corresponding spot on the surface, and the rate of the hybridization reaction. We present a theoretical model that incorporates both kinetics of the reversible hybridization reaction and diffusional transport of the labeled strands, and analyze DNA microarray hybridization using this model. Simulations are carried out in a geometrically realistic domain for labeled DNA concentrations corresponding to rare and abundant transcripts for typical assay conditions. The rate of strand diffusion in solution is shown to strongly affect the overall hybridization rate. We compute the minimum inter-spot spacing for replicate spots to enhance sensitivity. We also determine the hybridization time for which reliable estimates of the relative mRNA abundance of two species can be obtained using total fluorescence intensities. An analytical solution for the concentration distribution of mobile strands at intermediate hybridization times provides a convenient tool to calculate the mobile strand concentration profiles. This model provides a framework for the process analysis of all microarray assays currently used for genomic transcriptional analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chetan Gadgil, Andrew Yeckel, Jeffrey J Derby, Wei-Shou Hu. 2004-10-19. A diffusion-reaction model for DNA microarray assays.. https://doi.org/10.1016/j.jbiotec.2004.05.008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Aqueous flat-cells perpendicular to the electric field for use in electron paramagnetic resonance spectroscopy, II: design.

This paper builds on the work of Mett and Hyde [J. Magn. Reson. 165 (2003) 137]. Various aqueous flat-cell geometries in the perpendicular orientation have been studied using Ansoft High Frequency Structure Simulator (version 9.0, Pittsburgh, PA) and Computer Simulation Technology Microwave Studio (version 5.0, Wellesley Hills, MA). The analytic theory of Mett and Hyde has been refined to predict optimum dimensions of multiple sample cell structures including the effect of the sample holder dielectric properties and the interaction of the cells with each other on EPR signal strength. From these calculations and simulations we propose a practical multiple cell sample structure for use in commercial rectangular TE102 cavities that yields 2.0-2.3 times higher sensitivity relative to a single flat-cell in the nodal orientation. We also describe a modified TE102 resonator design with square rather than cylindrical sample-access stacks that is predicted to give a factor of 2.2-2.7 enhancement in EPR signal strength of a single flat-cell in the nodal orientation. These signal enhancements are predicted with sample holders fabricated from polytetrafluoroethylene. Additional improvement in EPR signal of up to 75% can be achieved by using sample holder materials with lower dielectric constants.

Computer-Aided Design↗

An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report.

Dental implants have had a major impact on the treatment of edentulous patients. Fixed complete dentures have allowed removable complete dentures to be replaced with fixed prostheses. A new treatment modality using immediately loaded implants placed with a CAD/CAM surgical template using a flapless surgical technique, then loaded with a prefabricated restorative prosthesis, is presented. This report describes the Teeth-in-an-Hour (Nobel Biocare, Yorba Linda, Calif) treatment provided for a patient.

Computer-Aided Design↗

A compact large voltage-compliance high output-impedance programmable current source for implantable microstimulators.

A new CMOS current source is described for biomedical implantable microstimulator applications, which utilizes MOS transistors in deep triode region as linearized voltage controlled resistors (VCR). The VCR current source achieves large voltage compliance, up to 97% of the supply voltage, while maintaining high output impedance in the 100 MOmega range to keep the stimulus current constant within 1% of the desired value irrespective of the site and tissue impedances. This approach improves stimulation efficiency, extends power supply lifetime, and saves chip area especially when the stimulation current level is high in the milliampere range. A prototype 4-channel microstimulator chip is fabricated in the AMI 1.5-microm, 2-metal, 2-poly, n-well standard CMOS process. With a 5-V supply, each stimulating site driver provides at least 425-V compliance and > 10 MOmega output impedance, while sinking up to 210 microA, and occupies 0.05 mm2 in chip area. A modular 32-site wireless neural stimulation microsystem, utilizing the VCR current source, is under development.

Computer-Aided Design↗