Objective surgical performance evaluation based on haptic feedback.

Abstract

In order to develop effective virtual reality training systems for surgery there is a need to provide appropriate sensory and performance feedback to the user. This paper aims to demonstrate a method by which performance data can be collected. This is used to investigate the effect of haptic feedback on performance. A PHANTOM desktop device was used in conjunction with a suturing simulation A pair of needle-holders was instrumented with strain gauges and attached to the stylus of the PHANTOM allowing the measurement of force application and time. Suturing performance was evaluated in terms of stitch completion time, peak force application, and the length and straightness of the stitch. The effect of the level of force feedback provided by the simulation and performance over time was considered. The results indicate that the presence of force feedback affected task completion time, peak force application and the straightness of the stitch. Task completion time was shown to increase with the level of force feedback provided. Performance was seen to improve over time in terms of task completion time and the accuracy ofthe stitch. The work has examined how the presence and level of force feedback affects performance of a simple task. The accuracy of haptic feedback is important in the design of surgical simulation systems to ensure effective training transfer. A data collection method by which objective performance evaluation can be made is demonstrated. The method can be applied to training using bench models, simulations and potentially in the operating theatre.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Louise Moody, Chris Baber, Theodoros N Arvanitis. 2002. Objective surgical performance evaluation based on haptic feedback.. https://pubmed.ncbi.nlm.nih.gov/15458106/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The feasibility of three-dimensional displays of the thorax for preoperative planning in the surgical treatment of lung cancer.

OBJECTIVE: Three-dimensional (3D) displays of anatomic structures have become feasible for preoperative planning in some surgical procedures. There have been no reports, however, on the use of 3D displays for surgical treatment of lung cancer. We hypothesized that 3D displays of the thorax are useful for preoperative planning for lung cancer. METHODS: Based on virtual reality technologies, we rendered 3D displays of the thorax from two-dimensional (2D) computed tomographic (CT) images of six anonymous patients, some of whom underwent surgical removal of lung cancer. For determining the resectability of lung cancer, we tested 17 participants with varying degrees of surgical skills to view 3D displays and read 2D CT images of these thoracic cavities in a randomized order. We measured their performance in terms of the accuracy of predicted resectability, the confidence of their prediction, planning time used, and workload experienced. RESULTS: The results demonstrated that viewing 3D displays of thoracic cavities has significant advantages over reading 2D CT images in determining the resectability of lung cancer: increasing the accuracy of predicted resectability by about 20%, enhancing the confidence of the prediction by about 20%, decreasing planning time by about 30%, and reducing workload by about 50%. All participants preferred viewing 3D displays to reading 2D CT images for preoperative planning. Junior residents found 3D displays of thoraces more useful than senior residents. CONCLUSIONS: It is feasible to use 3D displays of the thorax for preoperative planning in treating lung cancer. Using 3D displays in surgical treatment of lung cancer has potential benefits, once the technique is perfected.

Clinical Competence↗

The learning curve in the training of percutaneous nephrolithotomy.

OBJECTIVES: To investigate the learning curve in the training of percutaneous nephrolithotomy (PCNL). METHODS: A total of 104 PCNL cases were included in this evaluation to define the learning curve of a surgeon with no previous experience at performing solo PCNL. Two parameters of expertise were reviewed, namely the operation and fluoroscopic screening times. The operation time was calculated as the beginning of access with the needle until the nephrostomy tube was placed and secured. PCNL procedures were analyzed in seven sets of 15 cases regarding the operation and fluoroscopy times, stone size, stone clearance rate, blood transfusion rate, and estimated blood loss. RESULTS: The mean operation time was 2.4 h for the first 15 patients. It decreased to a mean of 1.5 h for cases 46 through 60. No further decrease in the operation time was observed after case 60. The fluoroscopic screening time was a peak of 17.5 min in the first 15 cases, whereas it dropped to a mean of 8.9 min for cases 46 through 60. The decline in the mean fluoroscopy screening time continued in cases 61 to 104, but the decline was not significant. There was no significant difference in stone size, stone clearance rate, blood transfusion rate, and estimated blood loss among each set of cases. CONCLUSIONS: This study suggests that the surgical competence in PCNL can be reached after 60 cases. PCNL and fluoroscopy times drop to a steady-state level after performing 60 procedures.

Clinical Competence↗

Critical overview of the management of neonatal jaundice in the UK.

AIM: To determine the current management of early neonatal jaundice in the UK and to evaluate whether the current practices are evidence based. METHODS: A questionnaire survey was carried out among identified lead paediatricians of neonatal intensive care units. RESULTS: The survey found markedly differing practices for the recognition, investigation and treatment of neonatal jaundice. This applies particularly to confirmation of the clinical suspicion of jaundice; use of invasive and non-invasive technologies for diagnosis; preferred wavelength and intensity of light used for treatment; and whether birth weight, gestational age and postnatal age should influence treatment. CONCLUSION: The study found a lack of consistency in the management of jaundiced infants in the UK. The evidence-based practice currently available does not appear to have been incorporated into treatment protocols.