Search PubMed⌕ Search

PubMed · 15441793

[Vertebrotherapy table].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F COSTE, P GALMICHE. 1950. [Vertebrotherapy table].. https://pubmed.ncbi.nlm.nih.gov/15441793/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Metacarpal shaft fractures of the fingers: treatment with interosseous loop wire fixation and immediate postoperative finger mobilisation in a wrist splint.

It is widely believed that interosseous loop wire fixation of metacarpal shaft fractures alone is not rigid enough to allow immediate postoperative mobilisation. In this report, the author reviews the results in 36 cases of metacarpal shaft fractures of the fingers treated by interosseous loop wire fixation and immediate postoperative mobilisation of all finger joints. The study included 30 males and six females, with a mean age of 31 (range 12-52) years. The fracture pattern was transverse in 26 and oblique, or spiral, in the remaining 10 patients. Following loop wire fixation, the wrist was immobilised using a volar plaster splint for 3 weeks but all finger joints were mobilised immediately after surgery. After a mean follow-up of 8 weeks, all patients, except two, had regained full range of motion of the fingers and no complications were noted. It was concluded that interosseous loop wire fixation of metacarpal shaft fractures is rigid enough to allow immediate postoperative finger mobilisation in a wrist splint and achieve good functional results.

Bone Wires↗

Corrosion of stainless steel sternal wire after long-term implantation.

A variety of metallic components have been used in medical devices where lifelong durability and physical strength are demanded. To investigate the in vivo changes of implanted metallic medical devices in humans, stainless steel sternal wires removed from patients were evaluated. Stainless steel (316L) sternal wires removed from four patients after 10, 13, 22, and 30 years of implantation were evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Macroscopically, the removed specimens maintained their metallic luster and color. Under SEM, small holes were observed sporadically at 10 years and they tended to connect in the drawing direction. The longer the implanted duration, the more numerous and deeper were the crevices observed. By EDS, sulfur, phosphorus, and calcium were identified in all areas at 10 years, in addition to the component elements of stainless steel, comprising iron, chromium, nickel, and manganese. Corrosion products observed at 30 years were identified as calcium phosphate. In conclusion, stainless steel sternal wires develop corroded pores that grow larger and deeper with time after implantation; however, the pores remain shallow even after decades of implantation and they may not be a cause of mechanical failure. An amount of metal ions equivalent to the corroded volume must have been released into the human body, but the effect of these metal ions on the body is not apparent.

Bone Wires↗