Search PubMed⌕ Search

PubMed · 15383712

Monochromatic polycapillary imaging utilizing a computed radiography system.

Abstract

A fundamental study on quasi-parallel radiography using a polycapillary plate and a copper-target x-ray tube is described. In the experiments, the tube voltage was regulated from 12 to 22 kV, and the tube current was regulated within 3.0 mA by the filament temperature. The exposure time was controlled in order to obtain optimum x-ray intensity, and the maximum focal spot dimensions were approximately 2.0 x 1.5 mm. The thickness and the inner capillary tube diameter of the polycapillary were 1.0 mm and 25 microm, respectively. Monochromatic x-rays were produced using a 10 microm-thick nickel filter with a tube voltage of 17 kV, and these rays were formed into quasi-parallel beams by the polycapillary. The radiogram was taken using a computed radiography system utilizing imaging plates. In the measurement of image resolution, the spatial resolution hardly varied according to increases in the distance between the resolution-test chart and imaging plate using a polycapillary. A 50 microm tungsten wire could be observed, and fine blood vessels of approximately 100 microm were visible in angiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michiaki Sagae, Eiichi Sato, Yasuomi Hayashi, Etsuro Tanaka, Hideo Mori, Toshiaki Kawai, Haruo Obara, Toshio Ichimaru, Kazuyoshi Takayama, Hideaki Ido. 2004. Monochromatic polycapillary imaging utilizing a computed radiography system.. https://pubmed.ncbi.nlm.nih.gov/15383712/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗