Search PubMedSearch

PubMed · 1538338

Framework design for bone-anchored fixed prostheses.

Abstract

Fixed implant-supported restorations for edentulous patients provide excellent function, but can often be difficult to maintain. Design considerations are important to enable the patient to maintain optimal oral hygiene while complementing and enhancing the structural integrity of the prosthesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S N White, S G Lewis. 1992. Framework design for bone-anchored fixed prostheses.. https://doi.org/10.1016/0022-3913(92)90465-m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Separation of components of human globulins by capillary zone electrophoresis using a linear polyacrylamide-coated capillary.

Eleven commercially available protein preparation from human serum were subjected to capillary zone electrophoresis (CZE) using a linear polyacrylamide-coated capillary at pH 7.4. Transferrin, complement C3 and C-reactive protein were each separated into one major peak and several minor peaks. alpha 1-Antitrypsin was separated into two major peaks and three minor peaks. alpha 2-HS-glycoprotein showed four major peaks with a leading shoulder. Haptoglobin, alpha 2-macroglobulin, alpha 1-acid-glycoprotein and prealbumin were detected as relatively wide peaks. Ceruloplasmin showed one major peak with notches, and two minor and several notched peaks. Only low density lipoprotein showed no peaks. A mixture of five of the protein preparations was separated into individual components, as well as individual isoforms. When the same mixture was analyzed by CZE using an uncoated capillary, a much poorer resolution was obtained. Application of this CZE system to albumin-depleted serum demonstrated that it is very useful for analyzing globulin components in serum.

Acrylic Resins

The staining of acidic proteins on polyacrylamide gels: enhanced sensitivity and stability of "Stains-all" staining in combination with silver nitrate.

A number of acidic proteins, such as those found in bone and dentin, are poorly resolved on acrylamide gels using Coomassie blue or silver nitrate staining. The cationic dye Stains-all allows visualization and identification of these proteins due to their differential staining: highly acidic proteins stain blue and intact proteoglycans stain purple, whereas less acidic proteins stain pink. However, the use of Stains-all is limited due to relatively poor staining sensitivity and lack of stability to light. A procedure which addresses these deficiencies has been developed utilizing established protocols for Stains-all staining followed by silver nitrate incubation and development. In this way, phosphoproteins such as osteopontin, bone sialoprotein, dentin phosphophoryn, and other acidic glycoproteins are visualized at higher sensitivity (greater than fivefold) and staining stability than normally achieved with just Stains-all. The protocol stains a greater variety of proteins than a combined alcian blue/silver staining procedure previously described. Utilizing the Stains-all/silver protocol, porcine bone osteopontin, a protein not visualized by standard silver staining, can be observed in amounts as little as 0.25 ng on polyacrylamide gels. Furthermore, densitometric scans demonstrate that the staining intensity is proportional to osteopontin amount and can be used for quantification over a range from 0.25 to 50 ng.

Acrylic Resins

A laboratory evaluation of the construction of resin-bonded cast restorations.

OBJECTIVE: To compare the effect of two construction techniques and two pattern materials on the fit of resin-bonded cast restorations. DESIGN: In-vitro study carried out by one operator. SETTING: Postgraduate university hospital. SUBJECTS AND METHODS: 65 nickel-chrome castings were constructed using refractory die and lift-off techniques with wax and acrylic resin pattern material. They were cemented onto master silver dies, embedded in self-curing acrylic resin and sectioned along their long axes. Interfacial distance between the master silver die and casting was measured. RESULTS: A significant different between the range of figures in each group (Mann-Whitney Test, P < 0.01) was found. Construction techniques can be ranked in order of fit of castings: 1. Refractory die, wax patterns: 42.6 microns (SD 12.03). 2. Refractory die, acrylic resin patterns: 53.7 microns (SD.16.06).3. Conventional technique, acrylic resin patterns: 85.5 microns (SD 31.62). 4. Lift-off technique, wax patterns: 139 microns (SD 53.15).5. Lift-off technique, acrylic patterns: 172.8 microns (SD 74.04). CONCLUSIONS: Castings constructed using refractory die technique and subsequently cemented resulted in a more accurate and less variable fit than those produced with the lift-off technique. Wax patterns lead to more accurate castings than acrylic resin and locating indentations may interfere with the cementation of castings when lift-off techniques are used.

Acrylic Resins