Search PubMedSearch

PubMed · 1533975

Breathing circuits.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Haskins. 1992. Breathing circuits.. https://doi.org/10.1016/s0195-5616(92)50648-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of the water content of soda lime on compound A concentration in the anesthesia circuit in sevoflurane anesthesia.

BACKGROUND: Sevoflurane anesthesia is usually performed with fresh gas flow rates greater than 2 l/min due to the toxicity of compound A in rats and limited clinical experience with sevoflurane in low-flow systems. However, to reduce costs, it would be useful to identify ways to reduce compound A concentrations in low-flow sevoflurane anesthesia. This goal of this study was to determine if compound A concentrations can be reduced by using soda lime with water added. METHODS: Low-flow sevoflurane anesthesia (fresh gas flow of 1 l/min) was performed in 37 patients using soda lime with water added (perhydrated soda lime) or standard soda lime as the carbon dioxide (CO2) absorbent. The soda lime was not changed between patients, but rather was used until CO2 rebreathing occurred. The perhydrated soda lime was prepared by spraying 100 ml distilled water onto 1 kg fresh soda lime, and water was added only when a new bag of soda lime was placed into the canister. Compound A concentrations in the circle system, soda lime temperatures, inspired and end-tidal CO2 and end-tidal sevoflurane concentrations, and CO2 elimination by the patient were measured during anesthesia. RESULTS: Compound A concentrations were significantly lower for the perhydrated soda lime (1.9 +/- 1.8 ppm; means +/- SD) than for the standard soda lime (13.9 +/- 8.2 ppm). No differences were seen between the two types of soda lime with regard to the temperature of the soda lime, end-tidal sevoflurane concentrations, or CO2 elimination. Compound A concentration decreased with the total time of soda lime use for both types of soda lime. The CO2 absorption capacity was significantly less for perhydrated soda lime than for standard soda lime. CONCLUSIONS: Compound A concentrations in the circuit can be reduced by using soda lime with water added. The CO2 absorption capacity of the soda lime is reduced by adding water to it, but this should not be clinically significant.

Anesthesia, Closed-Circuit

Anaesthesia circuits, humidity output, and mucociliary structure and function.

We compared the effects of humidity delivered by the circle system at low fresh gas flows (FGF) with a conventional two-limb and coaxial circuit on the structure and function of the tracheobronchial epithelium in dogs. Animals were anaesthetized and mechanically ventilated using an anaesthesia ventilator to maintain normocarbia. Group I (control) animals received a FGF equal to the required minute ventilation mimicking an open circuit technique. Group II and III animals had FGF set at 20% of the required minute ventilation. Group II used a two-limb circuit and Group III used a coaxial circuit. Relative humidity and temperature of inspired gases were measured at baseline and hourly afterwards. In the first experiment, biopsies of the tracheobronchial tree were obtained bronchoscopically at baseline and then hourly for six hours. Microscopic examination of these samples allowed calculation of mean ciliary length. In the second experiment, tracheal mucus flow velocity (TMFV) was measured at baseline and hourly afterward, using a cinebroncho-fibrescopic method. Delivered absolute humidity was greatest with low FGF and the coaxial circuit, followed by low FGF and a conventional circuit, and high FGF (15 +/- 1.4 vs 9 +/- 0.8 vs 5 +/- 0.4 mg H2O, P < 0.01) after two hours. Mean cilia length (micron) and TMFV (mm/min) fell during the first hour in all three groups. At hour two TMFV returned to baseline in Group III and was significantly greater than Groups I and II (0.8 +/- 0.4 vs 8.6 +/- 1.1 vs 15.4 +/- 2.1, P < 0.001). Mean ciliary length demonstrated a similar pattern with reductions from baseline in all three groups for the first two hours. Groups II and III had an increase in cilia length beginning at hour three and were both significantly greater than Group I at hours 3 through 6 (1.3 +/- 0.5 vs 3.2 +/- 1.1 vs 4.2 +/- 0.8, P < 0.001). Alterations in tracheobronchial structure and function result from exposure to dry gases and are amplified by the duration of exposure. Our findings suggest a minimum of 12 to 15 mg H2O/l is necessary to prevent these alterations. In this study, the combination of low FGF and a coaxial anaesthesia circuit reached this minimum threshold more quickly than a conventional two-limb circuit.

Anesthesia, Closed-Circuit