Personalized ventilation.

Abstract

UNLABELLED: The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard to physiological and psychological response, clothing insulation, activity, air temperature and air movement preference, etc. Environmental conditions acceptable for most occupants in rooms may be achieved by providing each occupant with the possibility to generate and control his/her own preferred microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice. Performance criteria are defined. Recommendations for design of PV that would be in compliance with the criteria are given. Future research needed on the topic is outlined. PRACTICAL IMPLICATIONS: Personalized ventilation can improve occupants' comfort, decrease SBS symptoms and reduce the risk of transmission of contagion between occupants in comparison with total volume ventilation. However in order to perform efficiently in rooms in practice, the design (air distribution, control, etc.) has to be carefully considered together with type of occupant activity (occupancy rate, occupied density, etc.).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A K Melikov. 2004. Personalized ventilation.. https://doi.org/10.1111/j.1600-0668.2004.00284.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Studies on the efficacy of Chloramine T trihydrate (N-chloro-p-toluene sulfonamide) against planktonic and sessile populations of different Legionella pneumophila strains.

Effectiveness of Chloramine T trihydrate (N-chloro-p-toluene sulfonamide) on both planktonic and sessile populations of different Legionella pneumophila strains was assessed. Although Chloramine T is a recommended commercial formulation for disinfecting cooling towers, there is a lack of published data about the efficacy of this compound against both planktonic and sessile populations of L. pneumophila. Planktonic L. pneumophila strains were suspended in tap water and sessile L. pneumophila strains were grown on stainless steel which is used in the construction of cooling towers, followed by exposure to the biocide. The sensitivity of both planktonic and sessile populations of L. pneumophila strains was different. The biocide was found effective below recommended dosages (0.1-0.3%) against planktonic populations of L. pneumophila, whereas it was determined that higher dosages than those recommended were required for sessile populations of L. pneumophila. The results indicated that studying only the planktonic populations of L. pneumophila for biocide tests might not be sufficient to provide information about the optimum dosage and contact time. Therefore, efficacy has to be tested on both planktonic and sessile bacteria.

Air Conditioning↗

[Legionella outbreak in Amsterdam: a cooling tower as the source].

During the period 6-28 July 2006, 30 confirmed cases of Legionella infection were identified in Amsterdam, 2 of which were fatal. All had a positive urinary antigen test, by which Legionella pneumophila serogroup I could be demonstrated. Consultations between the parties involved in the control of infectious diseases started on July 7th, as soon as it became clear that there was an outbreak. On July 10th it was established that relatively many of these patients lived in the eastern part of the city centre. After a study of the prevailing winds during the past 3 weeks, the search for installations containing water was started. A cooling tower in the town centre was closed on July 11th by way of precaution. During the following week, this tower was proven to be the source of the outbreak.

Air Conditioning↗

Alterations in health examination items and skin symptoms from exposure to ultra-low humidity.

OBJECTIVES: Several lines of evidence have shown that insufficient humidity could result in health problems but no studies have been performed in ultra-low humidity (ULH) environments. The aims of this study are to investigate the health examination items alterations and skin symptoms of workers exposed to ULH environment based on a longitudinal study design. METHODS: Twelve male ULH (RH = 1.5%) workers and 12 age-sex-matched reference workers were selected. The examination items in blood and urine as well as the skin problems were compared between ULH workers and controls, and between ULH workers in 2000 and 2003. Biochemistry analysis of blood and urine were implemented from annual health examinations. Information on skin symptoms and diseases were obtained from a structured questionnaire in 2000 and 2003. RESULTS: The alterations in mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and total cholesterol in blood analysis and only sediment-WBC in urine analysis were found significantly different in 2000. These changes were almost fully recovered in 2003 although a consistently significant elevation in the urine specific gravity was found during the 3-year follow-up period. Skin disorders, however, showed an earlier elevated itching symptom in lower limb and pretibial that developed to physician-diagnosed contact dermatitis. CONCLUSIONS: Long-term ULH exposure could cause progressive pathological changes in the skin and urine concentration elevation. Because low humidity condition occurs frequently in air-conditioned buildings, the findings of this study suggest the population long-term exposed to low humidity should be cautious about health manifestations living in a low humidity environment. While the indoor environment is equipped with an air-conditioner, continuous monitoring on the humidity is recommended.

Air Conditioning↗