Abstract

During the last decade deep brain stimulation (DBS) has become a routine method for the treatment of advanced Parkinson's disease (PD), leading to striking improvements in motor function and quality of life of PD patients. It is associated with minimal morbidity. The rationale of targeting specific structures within basal ganglia such as the subthalamic nucleus (STN) or the internal segment of the globus pallidus (GPi) is strongly supported by the current knowledge of the basal ganglia pathophysiology, which is derived from extensive experimental work and which provides the theoretical basis for surgical therapy in PD. In particular, the STN has advanced to the worldwide most used target for DBS in the treatment of PD, due to the marked improvement of all cardinal symptoms of the disease. Moreover on-period dyskinesias are reduced in parallel with a marked reduction of the equivalent daily levodopa dose following STN-DBS. The success of the therapy largely depends on the selection of the appropriate candidate patients and on the precise implantation of the stimulation electrode, which necessitates careful imaging-based pre-targeting and extensive electrophysiological exploration of the target area. Despite the clinical success of the therapy, the fundamental mechanisms of high-frequency stimulation are still not fully elucidated. There is a large amount of evidence from experimental and clinical data that stimulation frequency represents a key factor with respect to clinical effect of DBS. Interestingly, high-frequency stimulation mimics the functional effects of ablation in various brain structures. The main hypotheses for the mechanism of high-frequency stimulation are: (1) depolarization blocking of neuronal transmission through inactivation of voltage dependent ion-channels, (2) jamming of information by imposing an efferent stimulation-driven high-frequency pattern, (3) synaptic inhibition by stimulation of inhibitory afferents to the target nucleus, (4) synaptic failure by stimulation-induced neurotransmitter depletion. As the hyperactivity of the STN is considered a functional hallmark of PD and as there is experimental evidence for STN-mediated glutamatergic excitotoxicity on neurons of the substantia nigra pars compacta (SNc), STN-DBS might reduce glutamatergic drive, leading to neuroprotection. Further studies will be needed to elucidate if STN-DBS indeed provides a slow-down of disease progression.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sorin Breit, Jörg B Schulz, Alim-Louis Benabid. 2004-08-19. Deep brain stimulation.. https://doi.org/10.1007/s00441-004-0936-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stimulation of the subthalamic nucleus in a patient with Parkinson disease and essential tremor.

BACKGROUND: The preferred surgical target for the treatment of Parkinson disease (PD) is either the internal globus pallidus or the subthalamic nucleus (STN); the target for treatment of essential tremor (ET) is the thalamic subnucleus ventralis intermedius (Vim). Some patients with PD have coexistent ET, and the identification of a single surgical target to treat both parkinsonian motor symptoms and ET would be of practical importance. OBJECTIVE: To describe the use of the STN target in deep brain stimulator (DBS) surgery to treat PD motor symptoms and the action-postural tremor of ET. DESIGN: Case report. PATIENT: A 62-year-old man had a greater than 30-year history of action-postural tremor in both hands, well controlled with beta-blockers for more than 20 years. He developed resting tremor, bradykinesia, and rigidity on his right side that progressed to his left side during the past 10 years. Dopaminergic medication improved his rigidity and bradykinesia, with only mild improvement of his resting tremor and no effect on his action-postural tremor. INTERVENTIONS: Left pallidotomy followed by placement of a left DBS in the Vim and subsequent placement of a right STN DBS. MAIN OUTCOME MEASURES: Control of symptoms of PD and ET. RESULTS: The left pallidotomy controlled the patient's parkinsonian motor symptoms on the right side of his body, but did not affect the action-postural component of his tremor. The symptoms on the left side of the body, including both an action-postural and a resting tremor (as well as the rigidity and bradykinesia), improved after placement of a single right STN DBS. CONCLUSION: Placement of an STN DBS should be considered as the procedure of choice for surgical treatment of patients with a combination of PD and ET.

Deep Brain Stimulation↗

Neurostimulation systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems.

PURPOSE: To evaluate magnetic field interactions at 1.5- and 3-Tesla for implantable pulse generators (IPGs) and radiofrequency (RF) receivers used for implantable neurostimulation systems. MATERIALS AND METHODS: Measurements of magnetically induced displacement force and torque were determined for 10 devices (seven IPGs, three RF receivers) used for neurostimulation systems. Displacement force and torque were assessed at various positions in 1.5- and 3-Tesla MR systems using standardized techniques. RESULTS: Four IPGs exhibited force ratios (magnetic attraction force/device weight) greater than 1.0, with the overall magnitude of the force ratio increasing significantly when comparing the 1.5-Tesla to the 3-Tesla MR system. Of the seven IPGs tested, one exhibited a torque ratio (magnetic induced torque/product of the device weight and length) greater than 1.0. The RF receivers displayed relatively strong magnetic field interactions at both 1.5- and 3-Tesla, exhibiting force and torque ratios greater than 1.0. CONCLUSIONS: The neurostimulation implants tested exhibited varying degrees of magnetic field interactions, with four of the seven IPGs and the three RF receivers exhibiting at least one MR-induced force or torque value greater than the effect of gravity. These findings have important implications for patients with these implants who are referred for MRI examinations.

Deep Brain Stimulation↗