Quantifying labial blood flow using optical Doppler tomography.

Abstract

OBJECTIVES: Changes in the oral microvasculature occur in a variety of diseases. Optical Doppler tomography (ODT) combines laser Doppler flowmetry with optical coherence tomography (OCT) to produce high-resolution tomographic images of biological tissues that also detect the velocity and direction of blood flow. The objective of this study was to determine the feasibility of ODT to image labial blood flow. A prototype ODT imaging system was constructed that characterized and measured labial blood flow in healthy subjects. MATERIALS AND METHODS: A prototype ODT instrument was constructed using a diode light source with a central wavelength of 1300 nanometers, a 40-nanometer spectral width and 2.4 microwatts output power. To verify the accuracy of the system, the flow rates of a phantom material (Intralipid) pumped through a capillary tube at various speeds was measured. To evaluate the clinical feasibility of the ODT prototye, the mucosal aspect of the upper and lower lips at the midline was imaged in 9 healthy volunteers. The sample arm of the instrument consisted of a fiberoptic probe with a 2-mm in diameter polished glass lens attached to the end. The probe was placed approximately 3 mm from the mucosal surface of the lip and oriented perpendicular to the surface. A motorized translation stage moved the fiber in a superior to inferior direction while the subject's head was stabilized by placing the chin into a chin rest. Imaging time for a 12-mm x 2.5-mm scan was approximately 64 seconds. RESULTS: The phantom experiments revealed that accuracy of this novel ODT prototype to measure flow was within 5%. In vivo labial blood flow velocity ranged from 11.8 to 43.1 mm/second in the upper lip and 8.2 to 53.2 mm/second in the lower lip. There were no statistically significant differences between flow rates in the upper and lower lips. OCT images and Doppler velocity signals were successfully integrated producing in vivo images of labial blood in all of the subjects (15 images). The resulting cross-sectional images revealed microscopic details of labial structures and, to the best of our knowledge, are the first ODT images of the labial microvasculature. CONCLUSIONS: The results of this in vivo study prove the feasibility of ODT to quantify labial blood flow and produce high spatial resolution images specifically localizing vessels anatomically. ODT provides both flow speed and flow direction information. ODT is noninvasive and offers the advantages of high volumetric flow sensitivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Linda L Otis, Daquing Piao, Carolyn W Gibson, Quing Zhu. 2004. Quantifying labial blood flow using optical Doppler tomography.. https://doi.org/10.1016/j.tripleo.2004.03.030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-field magnetic resonance imaging of meniscoids in the zygapophyseal joints of the human cervical spine.

STUDY DESIGN: Prospective in vitro study of meniscoids in the cervical zygapophysial joints. OBJECTIVES.: To assess the use of high-field magnetic resonance imaging (MRI) as a potential tool for evaluating meniscoids of the cervical zygapophysial joints. SUMMARY OF BACKGROUND DATA: Pain originating from the cervical spine is a frequent condition. It has been suggested that pathologic conditions of meniscoids within the zygapophysial joints may cause pain. METHODS: Six zygapophysial joints from one embalmed human body were investigated with a 3.0-T MR unit, equipped with a microimaging-set. MRIs were correlated with microanatomical sections. RESULTS: High-quality images of the meniscoids were obtained for all joints examined. There was a good correlation between the anatomic features derived from MRI and the microanatomical sections. CONCLUSIONS: High-field MRI was successfully implemented as a noninvasive method for imaging the meniscoids in cervical zygapophysial joints. The results of this in vitro study indicate that high-field MRI may be feasible in evaluating patients with cervical pain possibly related to meniscoid pathology.

Anatomy, Cross-Sectional↗

Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and cryosection images were acquired post mortem from a single mouse placed in a stereotactic frame with fiducial markers visible in all three modalities. The image data were coregistered to a common coordinate system using the fiducials and resampled to an isotropic 0.1 mm voxel size. Using interactive editing tools we segmented and labelled whole brain, cerebrum, cerebellum, olfactory bulbs, striatum, medulla, masseter muscles, eyes, lachrymal glands, heart, lungs, liver, stomach, spleen, pancreas, adrenal glands, kidneys, testes, bladder, skeleton and skin surface. The final atlas consists of the 3D volume, in which the voxels are labelled to define the anatomical structures listed above, with coregistered PET, x-ray CT and cryosection images. To illustrate use of the atlas we include simulations of 3D bioluminescence and PET image reconstruction. Optical scatter and absorption values are assigned to each organ to simulate realistic photon transport within the animal for bioluminescence imaging. Similarly, 511 keV photon attenuation values are assigned to each structure in the atlas to simulate realistic photon attenuation in PET. The Digimouse atlas and data are available at http://neuroimage.usc.edu/Digimouse.html.

Anatomy, Cross-Sectional↗

Coronary artery stenosis quantification using multislice computed tomography.

RATIONALE AND OBJECTIVES: Reliable noninvasive detection of stenoses with multislice computed tomography (MSCT) is feasible. This study's aim was to analyze the agreement, correlation, and reliability of MSCT with conventional coronary angiography as the reference standard for quantification of coronary artery stenoses. MATERIALS AND METHODS: A total of 118 significant (at least 50%) coronary artery stenoses with a reference vessel diameter of at least 1.5 mm in 62 patients were analyzed by MSCT using 16 detector rows (Aquilion, Toshiba, Otawara, Japan), multisegment reconstruction, and voxel sizes of 0.35x0.35x0.5 mm. The degree of stenosis on MSCT and quantitative coronary angiography (QCA) was measured by correlating the difference between the reference vessel diameter (average of 2 measurements directly proximal and distal to the stenosis) and the stenotic vessel diameter to the reference vessel diameter. RESULTS: Correlation between the percent diameter stenosis determined by MSCT (78.2+/-13.6%) and QCA (76.0+/-14.8%) was significant (P<0.001) but only moderately so (R=0.51). Bland-Altman analysis revealed no systematic under- or overestimation with MSCT but large limits of agreements (+/-27.6%). Also the limits of agreement for interobserver agreement (reliability) of MSCT data were considerably large (+/-24.8%). Among the 27 coronary artery stenoses with a reference diameter of at least 3.5 mm, there was improved correlation (R=0.80) and the limits of agreement between MSCT and QCA were significantly smaller (+/-17.3%, P<0.008). The agreement between MSCT and QCA was not significantly different for stenoses with no calcification or only calcium spots (+/-28.2%) as compared with those with moderate-or-severe calcifications (+/-27.3%; P=0.8). MSCT allowed correct classification of coronary stenoses into low-grade (below 75%) and high-grade stenoses (at least 75%), in 62% (73 of 118). CONCLUSIONS: The accuracy and reliability of coronary artery stenosis quantification with MSCT using isotropic voxel sizes and multisegment reconstruction is still too low to recommend routine clinical application because of rather low agreement, correlation, and reliability. Despite these limitations, the current results demonstrate the potential of MSCT for reliable and accurate quantification of coronary artery stenoses in the near future provided that further improvements in spatial and temporal resolution will be achieved.

Anatomy, Cross-Sectional↗