Quantification in proteomics through stable isotope coding: a review.

Abstract

This review focuses on techniques for quantification and identification in proteomics by stable isotope coding. Methods are examined for analyzing expression, post-translational modifications, protein:protein interactions, single amino acid polymorphism, and absolute quantification. The bulk of the quantification literature in proteomics focuses on expression analysis, where a wide variety of methods targeting different features of proteins are described. Methods for the analysis of post-translational modification (PTM) focus primarily on phosphorylation and glycosylation, where quantification is achieved in two ways, either by substitution or tagging of the PTM with an isotopically coded derivatizing agent in a single process or by coding and selecting PTM modified peptides in separate operations. Absolute quantification has been achieved by age-old internal standard methods, in which an isotopically labeled isoform of an analyte is synthesized and added to a mixture at a known concentration. One of the surprises is that isotope coding can be a valuable aid in the examination of intermolecular association of proteins through stimulus:response studies. Preliminary efforts to recognize single amino acid polymorphism are also described. The review ends with the conclusion that (1) isotope ratio analysis of protein concentration between samples does not necessarily relate directly to protein expression and rate of PTM and (2) that multiple new methods must be developed and applied simultaneously to make existing stable isotope quantification methods more meaningful. Although stable isotope coding is a powerful, wonderful new technique, multiple analytical issues must be solved for the technique to reach its full potential as a tool to study biological systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Samir Julka, Fred Regnier. Quantification in proteomics through stable isotope coding: a review.. https://doi.org/10.1021/pr0340734

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Structural anomalies for a three dimensional isotropic core-softened potential.

Using molecular dynamics simulations we investigate the structure of a system of particles interacting through a continuous core-softened interparticle potential. We found for the translational order parameter t a local maximum at a density rho(t-max) and a local minimum at rho(t-min)>rho(t-max). Between rho(t-max) and rho(t-min), the t parameter anomalously decreases upon increasing pressure. For the orientational order parameter Q(6) a maximum was observed at a density rho(t-max)<rho(Qmax)<rho(t-min). For densities between rho(Qmax) and rho(t-min), both the translational (t) and orientational (Q(6)) order parameters have anomalous behavior. We know that this system also exhibits density and diffusion anomalies. We found that the region in the pressure-temperature phase diagram of the structural anomaly englobes the region of the diffusion anomaly that is larger than the region limited by the temperature of maximum density. This cascade of anomalies (structural, dynamic, and thermodynamic) for our model has the same hierarchy as that observed for the simple point charge/extended water.

Isotopes↗

Delta34S measurements of sulfur by multicollector inductively coupled plasma mass spectrometry.

An accurate and precise method for the determination of delta34S measurements by multicollector inductively coupled plasma mass spectrometry has been developed. Full uncertainty budgets, taking into consideration all the uncertainties of the measurement process, have been calculated. The technique was evaluated by comparing measured values with a range of isotopically enriched sulfur solutions prepared by gravimetric addition of a 34S spike. The gravimetric and measured results exhibited a correlation of R2 >0.999. Repeat measurements were also made after adding Na (up to 420 microg g(-1)) and Ca (up to 400 microg g(-1)) salts to the sulfur standard. No significant deviations in the delta34S values were observed. The Russell correction expression (Ingle, C.; Sharp, B.; Horstwood, M.; Parrish, R.; Lewis, D. J. J. Anal. At. Spectrom. 2003, 18, 219) was used to correct for mass bias on the 34S/32S isotope amount ratio from the mass bias observed for the 30Si/28Si isotope amount ratio. Consistent compensation for instrumental mass bias was achieved. Resolution of the measured delta34S values was better than 1 per thousand after consideration of all uncertainty components. The technique was evaluated for practical applications by measurement of delta34S for a range of mineral waters by pneumatic nebulization sample introduction and the analysis of genuine and counterfeit pharmaceuticals using both laser ablation sample introduction and liquid chromatography. For the former two cases polyatomic interferences were resolved by operating the MC-ICPMS in medium resolution, while for the chromatographic analyses polyatomic interferences were minimized by the use of a membrane desolvator, allowing the instrument to be operated at a resolution of 400.

Isotopes↗

Relationship between the time-dependence of a transient-state kinetic isotope effect and the location of complexes in a reaction sequence.

We prove here a new transient-state kinetic rule which states that the ratios of the first derivatives of kinetic isotope effect time courses, extrapolated to zero time, provide integral values which specify the precise step number in the reaction sequence in single isotope substituted reactions. This rule defines such absolute numbers even where the steps involved are too fast to provide measurable concentrations of intermediates and when the full reaction sequence is unknown.

Isotopes↗