Search PubMed⌕ Search

PubMed · 1523128

Time for tea?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Sadler. Time for tea?. https://pubmed.ncbi.nlm.nih.gov/1523128/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid analysis of sugars in fruit juices by FT-NIR spectroscopy.

A simple analytical procedure using FT-NIR and multivariate techniques for the rapid determination of individual sugars in fruit juices was evaluated. Different NIR detection devices and sample preparation methods were tested by using model solutions to determine their analytical performance. Aqueous solutions of sugar mixtures (glucose, fructose, and sucrose; 0-8% w/v) were used to develop a calibration model. Direct measurements were made by transflection using a reflectance accessory, by transmittance using a 0.5-mm cell, and by reflectance using a fiberglass paper filter. FT-NIR spectral data were transformed to the second derivative. Partial least-squares regression (PLSR) was used to create calibration models that were cross-validated (leave-one-out approach). The prediction ability of the models was evaluated on fruit juices and compared with HPLC and standard enzymatic techniques. The PLSR loading spectra showed characteristic absorption bands for the different sugars. Models generated from transmittance spectra gave the best performance with standard error of prediction (SEP) <0.10% and R(2) of 99.9% that accurately and precisely predicted the sugar levels in juices, whereas lower precision was obtained with models generated from reflectance spectra. FT-NIR spectroscopy allowed for the rapid ( approximately 3 min analysis time), accurate and non-destructive analysis of sugars in juices and could be applied in quality control of beverages or to monitor for adulteration or contamination.

Beverages↗

Enantiomeric purity determination of malic acid in apple juices by multi-beam circular dichroism detection.

A multi-beam circular dichroism (CD) detector which is easily constructed by inserting inexpensive optics into a conventional photo-diode array detector has an advantage of simultaneous detection of the absorbance and CD. The enantiomeric purity determination of malic acid in beverages was performed by this detection system. Malic acid when complexed with Cu(II) was found to have an absorbance maximum at around 750 nm. The L-malic acid-Cu(II) complex showed a positive Cotton effect in its absorbance band and its anisotropy factor (delta epsilon/epsilon) was relatively large at about 1/170. This complex was retained on a reversed-phase column with the addition of racemic 2-hydroxy-3-methylbutyric acid to the mobile phase as the ligand. A plot of the relative peak areas between the CD and the absorption (delta abs/abs) versus optical purity showed good linearity with a correlation coefficient of 0.999, and the precision expressed as the relative standard deviation of the errors from the regression line was +/-2.7% (2sigma). The accuracy of the proposed method was assessed by capillary electrophoresis. Eight commercially available juice products were analyzed using this method. Five of them were thought to be adulterated with synthetic malic acid.

Beverages↗

Inhibition of green tea catechins against the growth of cancerous human colon and hepatic epithelial cells.

The ability of (-)-epicatechin (EC), (-)-epigallocatechin (EGC) and (-)-epigallocatechin gallate (EGCG) to inhibit the growth of HCT 116 colorectal and Hep G2 hepatocellular carcinoma cells was examined by MTT and clonogenic assays (CA). The respective catechins inhibited the growth of HCT 116 more strongly than Hep G2. In MTT assay, IC(50) values of EGC and EGCG against HCT 116 grew smaller on prolongation of the exposure times of the cells to the catechins. In CA, however, these two catechins had IC(50) values ranging between 7.6+/-0.4 and 11.2+/-0.5 microM against the same cells regardless of the exposure times. EC showed much weaker growth inhibitions relative to the two aforementioned catechins.

Beverages↗