PubMed · 15222295

Comparison of prosthetic valve hydrodynamic function: objective testing using statistical multilevel modeling.

Abstract

BACKGROUND AND AIM OF THE STUDY: The performance of novel prosthetic heart valves is assessed using in-vitro hydrodynamic function tests. The study aim was to examine the problem of objective discrimination of hydrodynamic performance to determine significant differences between valve designs, and illustrate proposed methodology using data collected from five different polyurethane tri-leaflet valve designs. METHODS: Two engineering designs were manufactured with leaflets of the same polyurethane (GE, LE); design L was manufactured using three further leaflet materials of differing material modulus (LL, L4, L5). Six valves were made in each design, each tested at five flow rates in a standard hydrodynamic test rig, with five test replications for each valve. The data were analyzed using multilevel statistical modeling methods, allowing simultaneous comparison of multiple regression lines describing valve performance. The multilevel model is hierarchical in structure, in this case with two levels of data, describing individual valves at level 2 and test replicates at level 1. In all cases, the multilevel model uses the hydrodynamic function measure of interest, e.g. mean pressure gradient or leakage, with logarithmic transformation as required as the dependent variable, Y. The independent variable, X, is, in all cases, the natural logarithm of the RMS flow measured through the valve. RESULTS: The two-design multilevel model enabled quantitative discrimination of designs GE and LE, showing that design GE had significantly better hydrodynamic function overall than design LE in this case (mean pressure gradient was estimated as 0.93 mmHg lower at low cardiac output, 14.74 mmHg lower at 9.6 l/min). The five-design multilevel model showed clearly the relatively poor hydrodynamic performance of designs L4 and L5 compared with others. The procedure was straightforward, and produced a statistical comparison among valve designs that is not easily achieved by other means. CONCLUSION: This methodology provides a useful means of objective assessment of valve function for valve developers. Variance estimates provided by the analysis also provide a basis for quality control of valve production and testing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gillian M Bernacca, John H McColl, David J Wheatley. 2004. Comparison of prosthetic valve hydrodynamic function: objective testing using statistical multilevel modeling.. https://pubmed.ncbi.nlm.nih.gov/15222295/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Calibration of spectra from dispersive XAS beamlines.

The DXAS Calibration computer program provides a quantitative and automated solution to the problem of calibrating spectra from dispersive XAS beamlines. Such spectra, obtained in arbitrary energy units, are calibrated with respect to the absorption features of a supplied reference spectrum, which has been obtained under similar conditions on a calibrated beamline. In addition to basic energy coordinate transformation parameters, DXAS Calibration supplies instrument corrections to compensate for mismatches in instrument response functions between the dispersive and reference beamlines.

Equipment Failure Analysis↗

Measuring orthopedic implant wear on standard radiographs with a precision in the 10 microm-range.

The aim of this study has been to explore and verify whether the use of a previously designed Analysis-by-Synthesis algorithm is capable to precisely measuring implant wear. The abrasion of polyethylene particles is seen as the main reason for the loosening of prosthetic components in the hip. It lies in the sub-millimeter range, and precision is a crucial point in wear measurement. In the Analysis-by-Synthesis algorithm, the synthetic X-ray image of the implant is matched to its original X-ray projection. This intensity based approach and the use of X-ray images with their inherent high resolution allow principally precise measurements. Wear has been defined based on the estimated implant parameters and under minimization of the impact of the main sources of error. The latter was theoretically studied in a sensitivity analysis. The use of the algorithm was tested in vitro as well as in vivo. In experimental data, the accuracy and the impact of the pelvic position and orientation were studied. The precision was assessed using dual radiographs of 20 patients with total hip replacement. A standard deviation of 49 microm was found.

Equipment Failure Analysis↗

Behavior of metal implants used in ENT surgery in 7 Tesla magnetic resonance imaging.

Magnetic resonance imaging (MRI) has become increasingly important as an imaging technique in cross-sectional imaging of head and neck diseases. To investigate whether MRI examinations can be performed without risk in patients with metal implants even at higher field strengths, we examined different materials in 7 Tesla MRI. Implants near sensory organs like the middle ear or eye are of particular interest here. Using the 7 Tesla research MRI for small animals, we tested implants made of various metals like titanium, gold, gold/platinum, platinum/iridium, gold-plated silver, PTFE and stainless steel for heating, translocation and rotation according to a standardized protocol. A fiber optic temperature probe measured the heating of the implant before, during and after MRI scanning. None of the implants showed significant heating. The gold-plated stainless steel ventilation tube was the only implant to markedly change its position already in the Petri dish. Of the remaining implants, a trachea support ring, a nose dilatator and the wire from the ventilation tubes moved during vibration of the Petri dish. With exception of two implants, all implants changed positions in the water bath. In the swim test, the gold implants showed the least movement of all the implants. In this study, the properties of the non-ferromagnetic implant materials differed in the 7 Tesla MRI. Stainless steel ventilation tubes, the trachea support ring and the nose dilatator were not suited for the 7 Tesla MRI system, because they changed their position during MRI. In the case of ventilation tubes with a steel wire, the wire should be removed before MRI to prevent injury to the external auditory canal. There was a tendency for the pure gold implants to move less in the 7 Tesla MRI than all other tested materials. General statements cannot be made about the MRI suitability of different implants. Every implant should be individually examined to confirm its definitive MRI compatibility. Particularly, middle ear implants warrant special attention here due to their closeness to the oval window.

Equipment Failure Analysis↗