Search PubMed⌕ Search

PubMed · 1521684

Accuracy testing of three-dimensional digitizing systems.

Abstract

An accuracy test designed as a standard for digital occlusal wear measurement devices was applied to such a device designed by the authors. The test was used for quantitative determination of measurement error for a given angle of tangential contact with the inclined planes of the surface being measured. Using known dimensions of the digitizer contact tip and of a precision steel sphere, we determined trigonometrically the error in the Z-axis measurement due to the slope of any point on the surface of the sphere. These values were used for a point-by-point correction of data obtained from actual digitization of the sphere. The corrected values would equal zero if no mechanical source of error existed. These values, then, quantitatively indicated the accuracy (in microns) of the device as a function of the slope of the measurement point. The results indicated a linear relationship between surface slope angle and measurement error for the device tested.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E R Hewlett, M E Orro, G T Clark. 1992. Accuracy testing of three-dimensional digitizing systems.. https://doi.org/10.1016/0109-5641(92)90053-f

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Occlusion, TMDs, and dental education.

The paradigmatic shift to evidence-based dentistry (EBD) that relates to occlusal therapy, selective occlusal adjustment (OA) and stabilization splints therapy (SS) for TMDs has had an unfavourable impact on the teaching of many of the important aspects of occlusion needed in dental practice. The teaching of OA systematically in dental schools has been nearly abandoned because of the belief that OA is an irreversible procedure and gives the impression that it is without merit elsewhere in the management of occlusion. However, a particular dose of knowledge and practice of occlusion that is necessary for all aspects of dental care should be taught systematically in dental schools. The uses and misuses of OA and SS and their limitations should be emphasized because of their importance to bring clinical reality into the dental curriculum. Thus, and irrespective of EBD induced contradictions, OA and SS should still have a significant place in systematically teaching of occlusal therapy. However, there are many more aspects of the management of occlusion that should to be considered. Hopefully, because of their importance, other aspects of the management of occlusion will once again become a significant part of the dental curriculum.

Dental Occlusion↗