Search PubMed⌕ Search

PubMed · 15203696

Colour management: a workable solution.

Abstract

Within clinical photography, colour reproduction has always been a contentious issue. With the development of new technologies, the variables affecting colour reproduction have changed and photographers have altered practices, moving away from the realm of film to digital photographic imaging systems. In order to standardize the output of digital clinical images, the author researched, and successfully implemented, the GretagMacbeth EYE-ONE Pro colour management system. This system, which is maintained on a monthly basis, has ensured a colour-consistent, reliable and efficient workflow throughout the digital clinical set-up.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kirsteen Lattka. 2004. Colour management: a workable solution.. https://doi.org/10.1080/01405110410001667283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantification of bambuterol hydrochloride in a formulated product using solid-state NMR.

Carbon-13 NMR spectra of the stable polymorphs of solid bambuterol hydrochloride (BHC) and terbutaline sulfate (TBS) are reported and the resonances assigned with the aid of solution-state spectra. A protocol is presented for quantification of BHC in a formulation in lactose, together with TBS, relative to a reference peak from magnesium stearate. This protocol compares the intensity of an aromatic signal of BHC with that of the main-chain methylene carbons of the stearate. It is shown that the limit of detection (LOD) of BHC in this system under the conditions described is 0.5% with an effective limit of quantification (LOQ) of 1.0%. A calibration plot for the quantification is presented and the various factors affecting the accuracy of the measurements are described. No discernible differences are found in the spectra of physical mixtures of the components, whole tablets, and crushed or ground tablets.

Calibration↗

A validated liquid chromatography-mass spectrometry method for the determination of leukotrienes B4 and B5 produced by stimulated human polymorphonuclear leukocytes.

A validated high-performance liquid chromatography (HPLC)-mass spectrometry method has been developed for the simultaneous assay of leukotrienes (LTs) B4 and B5, derived from omega-6 arachidonic acid and omega-3 polyunsaturated fatty acids (PUFA), respectively, produced by human polymorphonuclear leukocytes (PMNLs) stimulated with calcium ionophore A23187. The HPLC separation of PMNL ether extracts was performed on a reversed-phase column using a gradient elution program of 15 mM ammonium acetate and MeOH. Detection was performed by electrospray ionization-single quadripole mass spectrometry using single ion reaction monitoring in the negative mode at m/z 333.3 [M-H](-) and m/z 335.2 for prostaglandin B2/LTB5 and LTB4, respectively. The calibration curves for LTB4 and LTB5 were linear over the ranges 165-990 and 0.825-13.2 ng/ml, respectively. The lower limit of quantification for LTB5 was 0.66 ng/ml. The mean absolute recoveries for LTB4 and LTB5 were 81+/-4.8% and 82+/-5.9%, respectively. The method is precise with mean interday CVs for LTB4 and LTB5 within 7.1-10.7, and 3.8-9.4%, respectively, and accurate (range of interday deviations for LTB4 and LTB5 were -7.8 to 1, and -5 to 9% , respectively). The method has been validated and is being applied to the simultaneous quantification of the leukotrienes B4 and B5 in stimulated PMNLs in a clinical protocol studying the influence of a diet enriched in omega-3 PUFA on various surrogate markers of inflammation in young cystic fibrosis patients.

Calibration↗

A method for determination of phosphatidylethanol from high density lipoproteins by reversed-phase HPLC with TOF-MS detection.

Phosphatidylethanol (PEth) is a unique phospholipid that is formed in the body only in the presence of ethanol. According to a new hypothesis, blood high-density lipoprotein (HDL) particles may act as carriers of PEth and mediate part of the antiatherogenic effects of moderate alcohol drinking. Liquid chromatographic method using reversed-phase C8 column and negative ion mode electrospray ionization-mass spectrometry detection with time-of-flight (TOF) instrument was developed for the determination of very small amounts of PEth that might be present on blood HDL particles. The samples used in the current study were human HDL spiked with PEth and internal standard phosphatidylpropanol (PProp). The use of reversed-phase column enabled a short analysis time of 19 min/injection, which is only one-third of the earlier normal-phase methods reported. Because of the narrow bore column (2.1 mm i.d.) and short analysis time, the solvent consumption was decreased. The sensitivity of detection obtained with TOF-MS was better than that of previous methods, with the detection limit being as low as 1 ng/ml in injected sample (20 pg on-column approximately 28 fmol PEth), corresponding to approximately 6.7 ng of PEth in milliliter of unprepared HDL. Good linearity of detection was obtained for a range of 1-100 ng/ml of PEth, whereas all of the deviations in precision and accuracy were less than 15%.

Calibration↗