Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus.

Abstract

The present study aimed to characterize the relationships between several variables reflecting bone microarchitecture assessed by both computed tomographic (CT) image analysis and histomorphometry (conventional CT system) at the calcaneus. A total of 24 cadaveric specimens were studied. The mean age at death was 78 +/- 10 years (range, 53-93 years). A total of 15 sagittal sections (1 mm in width and spaced 2 mm apart) were selected for CT analysis; 6 undecalcified sections (7 microm) were analyzed for histomorphometry. The histomorphometric analysis was performed on a Leica Quantimet Q570 image analyzer. Features measured by both methods were: bone volume/tissue volume (BV/TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N), interconnectivity index (ICI), number of nodes (N Nd), number of terminus (N Tm), node-to-node strut count (NNS), node-to-terminus strut count (NTS), terminus-to-terminus strut count (TTS), marrow space star volume (SV), Euler number (EN), and fractal dimension (FD). The coefficient of correlations' values (simple linear regression) between histomorphometry and CT image analysis varied according to the parameters selected. R values were high for BV/TV, Tb.N, and Tb.Sp (range, 0.69-0.90; P < 0.01). R values were less significant for some variables also obtained from the binary image: SV (0.5, P < 0.05) and EN (0.43, P < 0.05). Finally R values were also significant for (two) variables obtained from skeletonized images, i.e., N Nd (0.4, P < 0.05) and N Tm (0.61, P < 0.01). Other correlations were not statistically significant. Moreover, for some variables the relationships between the two methods (CT analysis and histomorphometry) seemed best-described by using nonlinear models. For example, a logarithmic model was more appropriate for SV (r = 0.71, P < 0.01), N Nd (r = 0.52, P < 0.01). Finally the relationship between apparent (App) N Tm and N Tm was most satisfying when using an exponential model (r = 0.64, P < 0.01). In conclusion, trabecular bone structure measures determined on CT images show highly significant correlations with those determined using histomorphometry. The level of correlation varies according to the type of method used for characterizing bone structure, however, and the strongest correlations were found for the most basic features (Parfitt's parameters). Finally, for some variables, nonlinear models seem more appropriate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Cortet, D Chappard, N Boutry, P Dubois, A Cotten, X Marchandise. 2004. Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus.. https://doi.org/10.1007/s00223-004-0086-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗