Search PubMed⌕ Search

PubMed · 15082

Dissolution from tablets prepared using ethyl cellulose microcapsules.

Abstract

Microcapsules containing sodium phenobartitone cores in ethyl cellulose have been used to prepare tablets at from 3-9 to 358-9 MPa compression pressures. The tensile strength of these tablets is related linearly to the core: wall ratio and to the microcapsule size. Dissolution of the drug from the microcapsules, is also related to the core:wall ratio and microcapsule size, but except at low compression pressures is almost independent of the pressure used during preparation. The tablet matrix remains intact during the dissolution and the equations developed by Schwartz, Simonelli & Higuchi (1968) are followed. Large microcapsules 1:2 core: wall ratio produce friable tablets with rapid release of contents.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Jalsenjak, C F Nicolaidou, J R Nixon. 1977. Dissolution from tablets prepared using ethyl cellulose microcapsules.. https://doi.org/10.1111/j.2042-7158.1977.tb11276.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid methods for determination of fluoxetine in pharmaceutical formulations.

Two different analytical methods for the quality control of fluoxetine in commercial formulations have been developed and compared: a spectrofluorimetric method and a capillary zone electrophoretic (CZE) method. The fluorescence emission values were measured at lambda=293 nm when exciting at lambda=230 nm. The CZE method used an uncoated fused-silica capillary and pH 2.5 phosphate buffer as the background electrolyte. The extraction of fluoxetine from the capsules consisted of a simple one-step dissolution with methanol/water, filtration and dilution. Both methods gave satisfactory results in terms of precision; the best results were obtained for the electrophoretic method, with RSD% values always lower than 2.0%. The accuracy was assessed by means of recovery studies, which gave very good results, between 97.5 and 102.6%. Furthermore, both methods also have the advantage of being very rapid.

Capsules↗

Simultaneous determination of fexofenadine and its related compounds by HPLC.

A simple reversed phase liquid chromatographic (RPLC) method has been developed and subsequently validated for the determination of fexofenadine hydrochloride and its related compounds A and B. The method utilizes a C8 column for the separation and determination of meta-isomer (related compound B). The separation was achieved using an Eclipse XDB C8, 5 microm, 4.6 x 150 mm column and a mobile phase comprising 1% triethylamine phosphate (pH 3.7), acetonitrile and methanol in the ratio 60:20:20 (v/v/v). 5-Methyl 2-nitrophenol has been used as internal standard for the purpose of quantitation of fexofenadine. The described method was linear over a range of 0.7-18.7 microg/ml for related compounds A and B and 60-750 microg/ml for assay of fexofenadine. The relative standard deviation (n=3) was 0.5% for the drug and 3.4% for related compounds. The intermediate precision was 0.79% (n=9) for assay and 5.16% (n=9) for related impurities. The mean recovery of both the related compounds were in the range of 94-103%. Limits of detection (LOD) and quantification (LOQ) for the related compounds A and B were 0.18, 0.12 and 0.56, 0.48 microg/ml, respectively. The precision of the method was checked by F-test using a reported method as reference and the calculated value (1.35) was found to be less than the table value at 95% confidence levels. The obtained results confirm that the method is highly suitable for its intended purpose.

Capsules↗

Comparison of several methods used for the determination of cephalosporins. Analysis of cephalexin in pharmaceutical samples.

The precision of UV absorbance of intact and acid degraded cephalosporins, ninhydrin, high performance liquid chromatography and iodometric methods used for analysis of cefoxitin, cefotaxime, cephazolin and cephalexin were compared. To obtain the calibration graphs the analytical signal used were: absorbance, first derivative absorbance, second derivative absorbance and H-point Standard Additions Method by using absorbance values at two selected wavelengths as analytical signal. These methods and calibration graphs were also used for the determination of cephalexin in pharmaceutical samples.

Capsules↗