Search PubMed⌕ Search

PubMed · 15064592

Minimum weight prediction methods cross-validated by the four-component model.

Abstract

UNLABELLED: The National Collegiate Athletic Association (NCAA) requires prediction of minimum weight (MW) for collegiate wrestlers. The rule was implemented to minimize unhealthy weight loss practices and requires assessment of body composition before the competitive season. PURPOSE: This study cross-validated the body composition methods of dual energy x-ray absorptiometry (DXA), leg-to-leg bioelectrical impedance analysis (BIA), hydrostatic weighing (HW), and skinfolds (SF) for predicting MW using a four-component criterion (4C). METHODS: Criterion MW was calculated by the 4C model using independent measurement of body density (BD), bone mineral content (BMC), and total body water (TBW). Subjects were 53 Division I athletes from the University of Wisconsin (mean +/- SD; age = 19.7 +/- 1.3 yr, height = 176.2 +/- 7.4 cm, weight = 75.6 +/- 8.9 kg). Accuracy, precision, and systematic bias were examined in the predictions. RESULTS: There were no significant differences in mean MW from HW (70.5 +/- 7.3 kg, P = 0.57), SF (70.5 +/- 7.2 kg, P = 0.29) BIA (70.6 +/- 7.6 kg, P = 0.39), DXA (70.3 +/- 7.5, P = 0.97), and the 4C criterion (70.3 +/- 7.4 kg). The regression for the relationships between 4C and HW (y = 0.994 x HW + 0.077 kg), 4C and SF (y = 1.003 x SF-0.437 kg), 4C and DXA (y = 0.942 x DXA + 4.034 kg), and 4C and BIA (y = 0.896 x BIA + 6.987 kg) did not significantly deviate from the line of identity. Pure error (PE) values ranged from 1.34 kg for HW to 3.08 kg for BIA. CONCLUSION: Comparable means, high correlations, regression lines that did not significantly deviate from the line of identity, and no systematic bias were found. However, the methods differed widely in precision. The best precision, based on SEE and PE values, were seen in the HW and SF methods. In conclusion, this rigorous four-component cross-validation study supports the NCAA methods as the most accurate and precise MW prediction methods in this sample.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Randall Clark, Cynthia Bartok, Jude C Sullivan, Dale A Schoeller. 2004. Minimum weight prediction methods cross-validated by the four-component model.. https://doi.org/10.1249/01.mss.0000121942.84630.6c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗