Search PubMed⌕ Search

PubMed · 15028648

Concurrent tonotopic processing streams in auditory cortex.

Abstract

The basis for multiple representations of equivalent frequency ranges in auditory cortex was studied with physiological and anatomical methods. Our goal was to trace the convergence of thalamic, commissural, and corticocortical information upon two tonotopic fields in the cat, the primary auditory cortex (AI) and the anterior auditory field (AAF). Both fields are among the first cortical levels of processing. After neurophysiological mapping of characteristic frequency, we injected different retrograde tracers at separate, frequency-matched loci in AI and AAF. We found differences in their projections that support the notion of largely segregated parallel processing streams in the auditory thalamus and cerebral cortex. In each field, ipsilateral cortical input amounts to approximately 70% of the number of cells projecting to an isofrequency domain, while commissural and thalamic sources are each approximately 15%. Labeled thalamic and cortical neurons were concentrated in tonotopically predicted regions and in smaller loci far from their spectrally predicted positions. The few double-labeled thalamic neurons (<2%) are consistent with the hypothesis that information to AI and AAF travels along independent processing streams despite widespread regional overlap of thalamic input sources. Double labeling is also sparse in both the corticocortical and commissural systems ( approximately 1%), confirming their independence. The segregation of frequency-specific channels within thalamic and cortical systems is consistent with a model of parallel processing in auditory cortex. The global convergence of cells outside the targeted frequency domain in AI and AAF could contribute to context-dependent processing and to intracortical plasticity and reorganization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Charles C Lee, Kazuo Imaizumi, Christoph E Schreiner, Jeffery A Winer. 2004. Concurrent tonotopic processing streams in auditory cortex.. https://doi.org/10.1093/cercor%2Fbhh006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Auditory topography and temporal response dynamics of canary caudal telencephalon.

To map the encoding of auditory cues in songbirds, multiunit electrophysiological responses to pure tone stimuli (250-5000 Hz) were recorded at 373 sites throughout the avian analogue of the mammalian auditory cortex in the caudal telencephalon of awake, restrained canaries. We found that a dorso-ventral tonotopic gradient from low to high frequency stimuli extends from the rostral field L2 to caudal-most caudo-medial nidopallium (NCM), similar to the frequency-dependent patterns of ZENK gene expression in canary NCM and to electrophysiological responses in other songbird species. However, response characteristics differ across the region. In field L2, responses are vigorous, phasic, and do not habituate to repeated presentations of the same stimulus. In an important subset of field L2 sites, tuning width narrows over the course of the response, which then terminates rapidly at stimulus offset. These properties are associated with inhibition at many nonpreferred frequencies and poststimulus inhibition at responsive frequencies. In contrast, NCM sites habituate to repeated sine waves, have wider tuning and lower amplitude responses, and rarely show inhibitory effects. Tuning curves in NCM are also flatter than those of field L2, and are often multipeaked. In addition, tuning width increases as the response unfolds and poststimulus excitation is often sustained in NCM. In sum, specific parts of the canary caudo-medial telencephalon differ in their response properties, suggesting differential roles in auditory processing. NCM properties, in particular, may allow for response integration across multiple spectrally varying stimulus elements, such as those that occur during birdsong.

Acoustic Stimulation↗

Better time-intensity trade revealed by bilateral giant magnetostrictive bone conduction.

Sound lateralization tests were performed to compare the magnet coil bone-conduction headphone with the giant magnetostrictive bone-conduction headphone using 18 healthy participants. Although, no significant difference between these bone-conduction headphones was obtained for the interaural time difference and interaural intensity difference, a significant difference was obtained for the time-intensity trade. This revealed that the difference between the headphones is apparent in the integration of the heterogeneous sensations of the time and intensity difference at the cognitive level, but no difference is apparent between the homogeneous sensations of the discrimination of interaural time difference or interaural intensity difference at the sensory level. It was concluded that the difference at the cognitive level indicates the better performance of the giant magnetostrictive headphone.

Acoustic Stimulation↗

Distributed current estimates using cortical orientation constraints.

Distributed source models of magnetoencephalographic (MEG) and electroencephalographic (EEG) data employ dense distributions of current sources in a volume or on a surface. Previously, anatomical magnetic resonance imaging (MRI) data have been used to constrain locations and orientations based on cortical geometry extracted from anatomical MRI data. We extended this approach by first calculating cortical patch statistics (CPS), which for each patch corresponding to a current source location on the cortex comprise the area of the patch, the average normal direction, and the average deviation of the surface normal from its average. The patch areas were then incorporated in the forward model to yield estimates of the surface current density instead of dipole amplitudes at the current locations. The surface normal data were employed in a loose orientation constraint (LOC), which allows some variation of the current direction from the average normal. We employed this approach both in the l(2) minimum-norm estimates (MNE) and in the more focal l(1) minimum-norm solutions, the minimum-current estimate (MCE). Simulations in auditory and somatosensory areas with current dipoles and 10- or 20-mm diameter cortical patches as test sources showed that applying the LOC can increase localization accuracy. We also applied the method to in vivo auditory and somatosensory data.

Acoustic Stimulation↗