Search PubMed⌕ Search

PubMed · 14997793

Options evaluated.

Abstract

As part of the comprehensive project "Sustainable Health Care Waste Management in Gauteng" en elaborate environmental and financial feasibility study has been made for selected provincial healthcare waste management scenarios. Furthermore, the study assessed the health, safety and socioeconomic impacts of the scenarios qualitatively and comparison was made with the prevailing containerisation and treatment used currently in Gauteng Province. The findings of the feasibility study show that compared to today's system of predominantly using disposable carboard boxes that are incinerated in incinerators with no flue gas cleaning systems and limited control of the combustion process, significant reductions of the emissions to the atmosphere can be achieved by improving the emission standards for incinerators and/or introducing non-burn treatment technologies. Also, it is clearly demonstrated that introduction of safer and reusable containerisation has a significant environmental benefit while providing a better and more occupationally safe service at a similar or slightly reduced cost. Finally the feasibility study demonstrates that while the type and amounts of emissions from incinerators with flue gas cleaning devises and alternative non-burn treatment technologies are materially different in nature and type it is difficult to clearly determine which of the two types of treatment technologies is globally and overall the least damaging in environmental terms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Torben Kristiansen, John Clements, Dave Baldwin, Kobus Otto. 2004. Options evaluated.. https://pubmed.ncbi.nlm.nih.gov/14997793/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Disposable devices for measuring intraocular pressure: a clinical study to assess their accuracy.

AIMS: We conducted a study to compare the accuracy of two commercially available disposable tonometry devices (the acrylic biprism, Tonosafe and the silicone shield, Tonoshield) with the standard Goldmann applanation tonometer (GAT). METHODS: A total of 80 eyes of 40 patients were randomly assigned to two groups. Group A (40 eyes) had the intraocular pressure IOP measured using GAT and the acrylic biprism (Tonosafe), while Group B (40 eyes) had IOP measured using GAT and the disposable silicone shield (Tonoshield). IOP was measured using the GAT both before and after the disposable device and average of the two standard Goldmann readings was compared with the IOP measured using the disposable devices. RESULTS: The mean difference in IOP in Group A was 0.29 mmHg (SD 0.54) (P=0.0018) while in Group B the mean difference in IOP was 2.09 mmHg (SD 1.23) (P<0.0001). The Altman-Bland method was used to assess the agreement between two methods of clinical measurement. This shows a positive bias of 0.29 (95% confidence interval (CI) 0.11-0.46) when using the disposable acrylic biprism and a positive bias of 2.09 (95% CI 1.69-2.48) with the silicone shield. CONCLUSION: The IOP recorded using the disposable acrylic biprism (Tonosafe) was in close agreement with the standard GAT. However, IOP readings obtained with the silicone shield (Tonoshield) tend to be higher than with the standard GAT. These facts should be kept in mind when recording IOP in clinical situations.

Disposable Equipment↗

Disposable twin gold electrodes for amperometric detection in capillary electrophoresis.

We describe a simple and easy way to construct gold microelectrodes for amperometric detection in capillary electrophoresis (CE). The gold microelectrodes, in single or twin sets, were obtained from recordable compact discs (gold-sputtered type), which present highly reproducible surface characteristics. The performance of these electrodes was evaluated by using a home-made CE equipment. The basic steps for the electrode construction are: drawing on a microcomputer; laser printing of the design on wax paper; heat-transfer of the toner onto the gold surface of a peeled recordable compact disc (CD-R); etching of the gold layer from unprinted regions; removal of the toner with a solvent; sealing of unused electrode areas with varnish. One electrode at a time was connected to a potentiostat (or two, to a bipotentiostat) and operated in a wall jet configuration relative to the CE capillary outlet. The amperometric signals were integrated for quantification purposes. Repetitive injections (n = 10) of a mixture containing iodide, ascorbic acid, dipyrone, and acetaminophen (20, 200, 500, and 100 microM), presented relative standard deviations of 2.9, 4.5, 6.1, and 4.0%, respectively. For these analytes, the detection limits (S/N = 3, 30 s of 100 mm hydrodynamic injection) were 0.1, 0.5, 3.1, and 1.1 microM, respectively.

Disposable Equipment↗