Search PubMed⌕ Search

PubMed · 14973765

Technical performance: relation between surgical dexterity and technical knowledge.

Abstract

Technical performance consists of surgical knowledge, judgment, and dexterity. Although assessment of surgical dexterity is now possible, assessing technical knowledge and its relation to dexterity has not been elucidated. Surgeons of varying experience were recruited to the skills laboratory to undertake three assessments: simple surgical dexterity (at 14 stations scored by motion analysis), an operating room equipment examination, and a novel error analysis. The scores were correlated, and p < 0.05 was deemed to be significant. Thirty surgeons were recruited; and construct validity was exhibited in all areas. Correlations were shown to exist between the two knowledge examinations (Spearman's rho = 0.39). Correlations existed between all dexterity task parameters and the equipment examination, whereas they existed for only 15 of the 28 parameters of the error examination and were always weaker. The stronger correlations between dexterity and instrument and operating room (OR) equipment reflect greater surgical experience and time spent in the OR. The weaker correlations between the error analysis and dexterity suggest that these skills are learned at different times. The identification of common surgical errors should be more formally taught to ensure greater uniformity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Simon Bann, Mansoor S Khan, Vivek K Datta, Ara W Darzi. 2004-01-08. Technical performance: relation between surgical dexterity and technical knowledge.. https://doi.org/10.1007/s00268-003-7071-z

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computational modeling of vascular anastomoses.

Recent development of computational technology allows a level of knowledge of biomechanical factors in the healthy or pathological cardiovascular system that was unthinkable a few years ago. In particular, computational fluid dynamics (CFD) and computational structural (CS) analyses have been used to evaluate specific quantities, such as fluid and wall stresses and strains, which are very difficult to measure in vivo. Indeed, CFD and CS offer much more variability and resolution than in vitro and in vivo methods, yet computations must be validated by careful comparison with experimental and clinical data. The enormous parallel development of clinical imaging such as magnetic resonance or computed tomography opens a new way toward a detailed patient-specific description of the actual hemodynamics and structural behavior of living tissues. Coupling of CFD/CS and clinical images is becoming a standard evaluation that is expected to become part of the clinical practice in the diagnosis and in the surgical planning in advanced medical centers. This review focuses on computational studies of fluid and structural dynamics of a number of vascular anastomoses: the coronary bypass graft anastomoses, the arterial peripheral anastomoses, the arterio-venous graft anastomoses and the vascular anastomoses performed in the correction of congenital heart diseases.

Anastomosis, Surgical↗

Caveolin-1 facilitates mechanosensitive protein kinase B (Akt) signaling in vitro and in vivo.

Mechanotransduction represents an integral part of vascular homeostasis and contributes to vascular lesion formation. Previously, we demonstrated a mechanosensitive activation of phosphoinositide 3-kinase (PI3-K)/protein kinase B (Akt) resulting in p27Kip1 transcriptional downregulation and cell cycle entry of vascular smooth muscle cells (VSMC). In this study, we further elucidated the signaling from outside-in toward PI3-K/Akt in vitro and in an in vivo model of elevated tensile force. When VSMC were subjected to cyclic stretch (0.5 Hz at 125% resting length), PI3-K, Akt, and Src kinases were found activated. Disrupting caveolar structures with beta-cyclodextrin or transfection of VSMC with caveolin-1 antisense oligonucleotides (ODN) prevented PI3-K and Akt activation and cell cycle entry. Furthermore, PI3-K and Akt were resistant to activation when Src kinases were inhibited pharmacologically or by overexpression of a kinase-dead c-Src mutant. alpha(V)beta3 integrins were identified to colocalize with PI3-K/caveolin-1 complexes, and blockade of alpha(V)beta3 integrins prevented Akt activation. The central role of caveolin-1 in mechanotransduction was further examined in an in vivo model of elevated tensile force. Interposition of wild-type (WT) jugular veins into WT carotid arteries resulted in a rapid Akt activation within the veins that was almost abolished when veins of caveolin-1 knockout (KO) mice were used. Furthermore, late neointima formation within the KO veins was significantly reduced. Our study provides evidence that PI3-K/Akt is critically involved in mechanotransduction of VSMC in vitro and within the vasculature in vivo. Furthermore, caveolin-1 is essential for the integrin-mediated activation of PI3-K/Akt.

Anastomosis, Surgical↗

Long-term outcome of bladder augmentation using living-related partial bladder transplantation in rats.

Long-term histopathologic changes after bladder augmentation (BA) in rats using living-related partial bladder transplantation (LPBTx) or conventional ileocystoplasty (ICP) were compared. In this study, BA (n = 37), LPBTx (n = 18), and ICP (n = 19) were performed in 16-wk-old Lewis rats. Five donors and seven nontransplanted normal Lewis rats (controls) were also studied. Rats that survived >10 mo after BA were killed after blood biochemistry and neobladder imaging. Harvested bladders were examined with hematoxylin and eosin and proliferating cell nuclear antigen (PCNA). When the rats were killed, there were 16 rats in the LPBTx group and 12 rats in the ICP group; ICP rats were significantly smaller than LPBTx rats (p < 0.05). Mean duration of follow-up for the LPBTX group was 17.3 mo, for the ICP group was 13.7 mo, for the donor group was 16.1 mo, and for the control group was 19.7 mo. Mean serum pH in the LPBTx group was 7.41 +/- 0.78 and in the ICP group was 7.25 +/- 0.38. Mean base excess in the ICP group was significantly lower than in the LPBTx group (p < 0.05). Incidence of bladder calculi in the LPBTx group (6.3%) was significantly lower than in the ICP group (33.3%; p < 0.05). There was no dysplasia/malignancy/increase in PCNA in the LPBTx group. PCNA increased in the ICP group, compared with controls (p < 0.05); two (16.7%) of 12 of ICP rats had dysplasia with mitosis. Bladder capacity increased in LPBTx and ICP compared with controls (both p < 0.05). We hope to show that BA using LPBTx may result in a neobladder with fewer complications than BA using ICP; LPBTx may also decrease the risk for malignancy.

Anastomosis, Surgical↗