Search PubMed⌕ Search

PubMed · 1487292

A three-dimensional architecture for a parallel processing photosensing array.

Abstract

A three-dimensional architecture for a photosensing array has been developed. This silicon based architecture consists of a 10 x 10 array of photosensors with 80 microns diameter, through chip interconnects to the back side of a 500 microns thick silicon wafer. Each photosensor consists of a 300 x 300 microns pn-junction photodiode. The following processes were used to create this photosensing architecture: 1) thermomigration of aluminum pads through an n-type silicon wafer; 2) creation of pn-junction photosensors on one side of the wafer; and 3) creation of aluminum pad ohmic contacts to the thermomigrated, through chip interconnects and the substrate on the back side of the wafer. The electrical and optical characteristics of the three-dimensional architecture indicates that it should be well suited as a photosensing framework around which a "silicon retina" could be built.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Johansson, M Abbasi, R J Huber, R A Normann. 1992. A three-dimensional architecture for a parallel processing photosensing array.. https://doi.org/10.1109/10.184705

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Artificial muscles based on liquid crystal elastomers.

This paper presents our results on liquid crystal (LC) elastomers as artificial muscle, based on the ideas proposed by de Gennes. In the theoretical model, the material consists of a repeated series of main-chain nematic LC polymer blocks, N, and conventional rubber blocks, R, based on the lamellar phase of a triblock copolymer RNR. The motor for the contraction is the reversible macromolecular shape change of the chain, from stretched to spherical, that occurs at the nematic-to-isotropic phase transition in the main-chain nematic LC polymers. We first developed a new kind of muscle-like material based on a network of side-on nematic LC homopolymers. Side-on LC polymers were used instead of main-chain LC polymers for synthetic reasons. The first example of these materials was thermo-responsive, with a typical contraction of around 35-45% and a generated force of around 210 kPa. Subsequently, a photo-responsive material was developed, with a fast photochemically induced contraction of around 20%, triggered by UV light. We then succeeded in preparing a thermo-responsive artificial muscle, RNR, with lamellar structure, using a side-on nematic LC polymer as N block.Micrometre-sized artificial muscles were also prepared. This paper illustrates the bottom-up design of stimuli-responsive materials, in which the overall material response reflects the individual macromolecular response, using LC polymer as building block.

Artificial Organs↗

A design framework to model retinas.

Neuro-engineering is providing biomedical engineers with technology to interface the nervous system, which is useful to create prosthetic devices to palliate sensorial or motor disabilities. Motivated by the success of cochlear implants for deaf patients, we are now facing the challenge of creating a prosthetic visual system for the blind. An artificial retina whose response to stimuli can be matched to biological ones is required. To make easier the task of modeling, tuning and testing these retinal models, we have created a software tool that allows flexible and parametric definition and testing of retina-like models. The program can be fed with a variety of video or image sources, and the results can be easily compared to biological recordings of retinal ganglionar activity in response to the same stimuli. This tool can be useful, not only for this prosthetic purpose, but for any other research involving bio-inspired image processing with a neuromorphic output.

Artificial Organs↗