Search PubMed⌕ Search

PubMed · 14751808

Validated high-performance liquid chromatographic method utilizing solid-phase extraction for the simultaneous determination of naringenin and hesperetin in human plasma.

Abstract

Naringenin and hesperetin, the aglycones of the flavanone glucosides naringin and hesperidin occur naturally in citrus fruits. They exert a variety of pharmacological effects such as antioxidant, blood lipid-lowering, anticarcinogenic and inhibit selected cytochrome P-450 enzymes resulting in drug interactions. A specific, sensitive, precise, and accurate solid-phase extraction high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of naringenin and hesperetin in human plasma was developed and validated. After addition of 7-ethoxycoumarin as internal standard, plasma samples were incubated with beta-glucuronidase/sulphatase, and the analytes were isolated from plasma by solid-phase extraction using C(18) cartridges and separated on a C(8) reversed phase column with methanol/water/acetic acid (40:58:2, v/v/v) as the eluent at 45 degrees C. The method was linear in the 10-300 ng/ml concentration range for both naringenin and hesperetin (r>0.999). Recovery for naringenin, hesperetin and internal standard was greater than 76.7%. Intra- and inter-day precision for naringenin ranged from 1.4 to 4.2% and from 1.9 to 5.2%, respectively, and for hesperetin ranged from 1.3 to 4.1% and from 1.7 to 5.1%, respectively. Accuracy was better than 91.5 and 91.3% for naringenin and hesperetin, respectively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Feras Imad Kanaze, Eugene Kokkalou, Manolis Georgarakis, Ioannis Niopas. 2004-03-05. Validated high-performance liquid chromatographic method utilizing solid-phase extraction for the simultaneous determination of naringenin and hesperetin in human plasma.. https://doi.org/10.1016/j.jchromb.2003.11.030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A validated stability-indicating HPLC with photodiode array detector (PDA) method for the stress tests of Monascus purpureus-fermented rice, red yeast rice.

A stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) with photodiode array (PDA) detection method was developed and validated for the assay of monacolin series compounds including monacolin K, L, J and their hydroxyl acid forms as well as dehydroxymonacolin K simultaneously in Monascus purpureus-fermented rice, red yeast rice. Well-resolved peaks of seven main compounds of monacolin family were profiled on a C(18) reverse-phase column using a linear gradient of 0.1% trifluoroacetic acid and acetonitrile as the mobile phase, and the detection wavelength was set at 237nm. The method was validated with respect to specificity, chromatographic parameters, linearity, precision, accuracy, limits of detection and quantitation. The stability stress testing for fermented red yeast rice powder was carried out to show the effects of high temperature (80 degrees C), high humidity at room temperature (92.5% RH, 25 degrees C), high humidity at high temperature (75% RH, 60 degrees C) and light (sunlight) in solid state. The results exhibited that monacolins decreased significantly under the conditions of high humidity at high temperature (75% RH, 60 degrees C) and sunlight. Monacolin K and its hydroxyl acid form would be dehydrolyzed and turned to dehydromonacolin K at high temperature (80 degrees C) while the monacolin K, J and L would be transformed into their corresponding hydroxyl acid forms under the condition of high humidity (92.5% RH, 25 degrees C). The indication is that monacolins in red yeast rice powder are light-sensitive and thermal-sensitive. Therefore, it has been suggested that the preparations containing monacolins be stored in the place of cool and lightproof. The proposed degradation pathways were discussed as well. The multi-components assay for stability of botanical products could provide much more information than the normal marker-orientation method.

Chromatography, High Pressure Liquid↗

Improved HPLC method for the simultaneous determination of tramadol and O-desmethyltramadol in human plasma.

This paper describes an HPLC method for the determination of tramadol and its major active metabolite, O-desmethyltramadol (ODT), in human plasma. Sample preparation involved liquid-liquid extraction with diethyl ether-dichloromethane-butanol (5:3:2, v/v/v) and back extraction with sulphuric acid. Tramadol, ODT and the internal standard, sotalol, were separated by reversed phase HPLC using 35% acetonitrile and an aqueous solution containing 20 mM sodium phosphate buffer, 30 mM sodium dodecyl sulphate and 15 mM tetraethylammonium bromide pH 3.9. Detection was by fluorescence with excitation and emission wavelengths of 275 and 300 nm, respectively. The method was linear for tramadol (3-768 ng/ml) and ODT (1.5-384 ng/ml) with mean recoveries of 87.2% and 89.8%, respectively. Intra- and inter-day precisions were 10.34% and 8.43% for tramadol and 9.43% and 8.75% for ODT at the respective limits of quantitation (3 and 1.5 ng/ml). Accuracy for tramadol ranged from 96.2% to 105.3%. The method was applied to a pharmacokinetic study of tramadol in human volunteers.

Chromatography, High Pressure Liquid↗

Prediction of drug absorption based on immobilized artificial membrane (IAM) chromatography separation and calculated molecular descriptors.

The aim of this study was to evaluate the usefulness of IAM chromatography in building a model that would allow prediction of drug absorption in humans. The human intestinal absorption values (%HIA) for 52 drugs with low to high intestinal absorption were collected from the literature. The retention (capacity factor, k') of each drug was measured by reverse-phase HPLC using an IAM.PC.DD2 column (prepared with phosphatidylcholine analogs, 12 microM, 300A, 15 cm x 4.6 mm) with an eluent of acetonitrile-0.1M phosphate buffer at pH 5.4. In addition, 76 molecular descriptors and solubility parameters for each drug were calculated using ChemSW from the 3D-molecular structures. Stepwise regression was employed to develop a regression equation that would correlate %HIA with molecular descriptors and k'. Human intestinal absorption was reciprocally correlated to the negative value of the capacity factor (-1/k') (R=0.64). The correlation was further improved with the addition of molecular descriptors representing molecular size and shape (molecular width, length and depth) solubility (solubility parameter, HLB, hydrophilic surface area) and polarity (dipole, polar surface area) (R=0.83). Experimentally measured IAM chromatography retention values and calculated molecular descriptors and solubility parameters can be used to predict intestinal absorption of drugs in humans. Developed QSAR can be used as a screening method in the designing of drugs with appropriate IA and for the selection of drug candidates in the early stage of drug discovery process.

Chromatography, High Pressure Liquid↗