Search PubMed⌕ Search

PubMed · 14750990

Object oriented database and electronic notebook for transmission electron microscopy.

Abstract

As high-resolution biological transmission electron microscopy (TEM) has increased in popularity over recent years, the volume of data and number of projects underway has risen dramatically. A robust tool for effective data management is essential to efficiently process large data sets and extract maximum information from the available data. We present the Electron Microscopy Electronic Notebook (EMEN), a portable, object-oriented, web-based tool for TEM data archival and project management. EMEN has several unique features. First, the database is logically organized and annotated so multiple collaborators at different geographical locations can easily access and interpret the data without assistance. Second, the database was designed to provide flexibility to the user, so it can be used much as a lab notebook would be, while maintaining a structure suitable for data mining and direct interaction with data-processing software. Finally, as an object-oriented database, the database structure is dynamic and can be easily extended to incorporate information not defined in the original database specification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Steven J Ludtke, Laurie Nason, Haili Tu, Liwei Peng, Wah Chiu. 2003. Object oriented database and electronic notebook for transmission electron microscopy.. https://doi.org/10.1017/s1431927603030575

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of the FearID earprint identification system.

The Forensic Ear Identification (FearID) research project was started in order to study the strength of evidence of earprints found on crime scenes. For this purpose, a sample of earprints from 1229 donors over three countries was collected. From each donor three left and three right earprints were gathered. On the one hand, operators denoted contours of the earprints to facilitate segmentation of the images, on the other anthropological specialists denoted anatomically specific locations. On the basis of this, methods for automated classification were developed and used for training of a system that classifies pairs of prints as 'matching' or 'non-matching'. Comparing lab quality prints, the system has an equal error rate of 4%. Starting from a reference database containing two prints per ear, hitlist behaviour is such that in 90% of all query searches the best hit is in the top 0.1% of the list. The results become less favourable (equal error rate of 9%) for print/mark comparisons.

Databases, Factual↗

Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database.

PURPOSE: Quantitative gated single-photon emission computed tomography (SPECT) is known to have high accuracy and precision for measurement of the principal cardiac functional parameters. We hypothesised that normal values for EF and LV volumes may differ among nationalities, and that optimal threshold values specific to the study population are required. METHODS: Among 4,670 consecutively registered patients for a J-ACCESS (Japanese investigation regarding prognosis based on gated SPECT) study from 117 hospitals, a total of 268 (149 women, 119 men) were selected who had no baseline cardiac diseases and had experienced no cardiac events during the preceding 3-year period. A gated SPECT study was performed with 99mTc-tetrofosmin and analysed with Cedars Sinai Medical Center's quantitative gated SPECT (QGS) software. The results in respect of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), and EDV, ESV and SV normalised by body surface area (EDVI, ESVI and SVI), were calculated and summarised to obtain normal limits. RESULTS: EF for women and men was 74 +/- 9% and 63 +/- 7%, respectively (p < 0.0001). EDV, ESV and SV were significantly smaller in women than in men. Based on multiple regressions for linear models, the primary and secondary predictors of EF, EDVI, ESVI were gender and age. By stepwise multiple regression analysis, a statistically significant third predictor for EDV, ESV, SV and SVI was body weight. No colinearity was found between age and body weight. Important factors for the studied Japanese population included a high incidence of small hearts in women and the relatively advanced age of the population (the mean age +/-SD was 64.1 +/- 10.0 years for women and 60.9 +/- 11.7 years for men). CONCLUSION: EF and volumes determined by gated SPECT with QGS were significantly affected by gender and age, with body weight as a third predictor for volumes. Moreover, the normal limits were so specific for the population studied that standards appropriate for the study in question should be utilised.

Databases, Factual↗