This report introduces a fully automated flow system for drug-dissolution studies based on the coupling of the sequential injection analysis (SIA) technique with a conventional dissolution apparatus. The methodology described was used for monitoring of dissolution profiles of prazosin hydrochloride (PRH) in pharmaceutical formulation. The very sensitive fluorimetric detection of PRH was performed at lambda(ex)=244 nm (lambda(em)>or=389 nm). Under the optimal conditions, the calibration curve was linear over the range 0.02-2.43 mg x l(-1) of PRH with R.S.D. 1.89, 1.23, and 1.80% (n=10) when determining 0.02, 1.22, and 2.43 mg x l(-1) of PRH in standard solutions, respectively. Equation of the calibration curve was calculated giving the following values: F=4.108 c-3.9 (n=6), r=0.9996. Detection limit was calculated 0.007 mg x l(-1) of PRH. The dissolution test of Deprazolin tablets was programmed for 60 min, with a continuous sampling rate of 70 h(-1) under conditions required by USP 26. Results obtained by SIA technique compared well with HPLC standard method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Z Legnerová, J Huclová, R Thun, P Solich. 2004-01-27. Sensitive fluorimetric method based on sequential injection analysis technique used for dissolution studies and quality control of prazosin hydrochloride in tablets.. https://doi.org/10.1016/j.japna.2003.08.014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A validated method for analysis of chromium picolinate in nutraceuticals by reversed phase high performance liquid chromatography.

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase Supelcosil LC-18 (250 x 4.6 mm, 5 microm) column. The mobile phase consisted of acetonitrile:water (40:60 v/v) at a fl ow rate of 0.8 mL/min. The UV-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 0.125 to 12.5 microg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quanti fi cation were 0.091 and 0.181 microg/mL, respectively.

Chromatography, High Pressure Liquid↗

RNA synthesis using 2'-O-(tert-butyldimethylsilyl) protection.

This chapter enables the reader to carry out the solid-phase synthesis of ribonucleic acid (RNA) using beta-cyanoethyl phosphoramidite chemistry combined with tert-butyldimethylsilyl protection of the ribose 2'-hydroxyl group. Phosphoramidite monomers are activated with 5-benzylmercapto-1H-tetrazole enabling fast and highly efficient coupling to the 5'-hydroxyl group of the support-bound oligonucleotide. On completion of the synthesis, the stepwise deprotection of the nucleobase, phosphate, and ribose protecting groups is carried out using optimized protocols. Subsequently the various high-pressure (performance) liquid chromatography (HPLC) procedures are described enabling the purification and analysis of the RNA. For this purpose anion-exchange and reversed-phase HPLC are used singly or in combination according to the final purity requirement of the RNA.

Chromatography, High Pressure Liquid↗

Solid-phase synthesis of circular oligonucleotides.

A protocol for the straightforward preparation of small circular oligodeoxyribonucleotides (2-28 nt) is reported. The assembly of the oligonucleotide chain (standard phosphoramidite chemistry) and cyclization by the phosphotriester method take place on a tailor-made nucleotide-derivatized solid support. Although cyclization yields are moderate, the procedure exploits a synthesis design that allows selective cleavage of the circular oligonucleotide from the support, which facilitates isolation of the target molecule by simple filtration.

Chromatography, High Pressure Liquid↗