Search PubMed⌕ Search

PubMed · 14722946

Qualitative colorimetric tests for solid phase synthesis.

Abstract

Results obtained in the application of these tests are summarized in Table II. We have encountered some variations in the reproducibility and accuracy of some tests. Due to the numerous factors that can influence colorimetric test results (e.g., test reagent stability, resin type, functional group interference, and lability of protecting group) we highly recommend performing a positive and a negative control for any test applied to a new synthesis. We also emphasize the importance of reagent solution purity on the outcome of test results, hence we strongly encourage the use of correctly prepared and carefully stored reactants. To minimize false results due to lability of the resin-product bond or the product itself (such as Fmoc-protected amino acids), colorimetric tests should be performed with the utmost immediacy in regards to completion of the step to be monitored. Hence the storage of resin over long periods of time (more than 24 h) before testing is not advisable. When the result of a colorimetric test is in doubt we advise repeating the test a few times until a reproducible result is obtained. The use of multiple tests for the same functional group may elucidate ambiguous or otherwise challenging cases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jesús Vázquez, Gregory Qushair, Fernando Albericio. 2003. Qualitative colorimetric tests for solid phase synthesis.. https://doi.org/10.1016/s0076-6879(03)69002-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterization of Sphingomonas aldehyde dehydrogenase catalyzing the conversion of various aromatic aldehydes to their carboxylic acids.

An aldehyde dehydrogenase gene, designated phnN, was isolated from a genome library of the 1,4-dimethylnaphthalene-utilizing soil bacterium, Sphingomonas sp. 14DN61. Escherichia coli expressing the phnN gene converted 1,4-dihydroxymethylnaphthalene to 1-hydroxymethyl-4-naphthoic acid. The putative amino acid sequence of the phnN gene product had 31-42% identity with those of NAD(+)-dependent short-chain aliphatic aldehyde dehydrogenases and a secondary alcohol dehydrogenase. The NAD(P)(+)-binding site and two consensus sequences involved in the active site for aldehyde dehydrogenase are conserved among these proteins. The PhnN enzyme purified from recombinant E. coli showed broad substrate specificity towards various aromatic aldehydes, i.e., 1- and 2-naphaldehydes, cinnamaldehyde, vanillin, syringaldehyde, benzaldehyde and benzaldehydes substituted with a hydroxyl, methyl, methoxy, chloro, fluoro, or nitro group were converted to their corresponding carboxylic acids. Interestingly, E. coli expressing phnN was able to biotransform a variety of not only aromatic aldehydes, but also aromatic alcohols to carboxylic acids.

Alcohols↗

Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives.

High performance liquid chromatography with atmospheric pressure ionization (API) mass spectrometry has been essential to a large number of quantitative analytical applications for a variety of compounds. Poor detection sensitivity however is a problem observed for a number of analytes because detection sensitivity can be affected by many factors. The two most critical factors are the chemical and physical properties of the analyte and the composition of the mobile phase. In order to address these critical factors which may lead to poor sensitivity, either the structure of the analyte must be modified or the mobile phase composition optimized. The introduction of permanently charged moieties or readily ionized species may dramatically improve the ionization efficiency for electrospray ionization (ESI), and thus the sensitivity of detection. Detection sensitivity may also be enhanced via introduction of moieties with high proton affinity or electron affinity. Mobile phase component modification is an alternative way to enhance sensitivity by changing the form of the analytes in solution thereby improving ionization efficiency. pH adjustment and adduct formation have been commonly used to optimize detection conditions. The sensitivity of detection for analytes in bio-matrices could also be enhanced by decreasing ion-suppression from the matrix through derivatization or mobile phase addition. In this review, we will discuss detection-oriented derivatization as well as the application of mobile phase additives to enhance the sensitivity of detection in liquid chromatograph/atmospheric ionization/mass spectrometry (LC/API/MS), focusing in particular on the applications involving small molecules in bio-matrices.

Alcohols↗

Biodiesel production from triolein and short chain alcohols through biocatalysis.

Oleic acid alkyl esters (biodiesel) were synthesised by biocatalysis in solvent-free conditions. Different commercial immobilised lipases, namely Candida antarctica B, Rizhomucor miehei, and Pseudomonas cepacia, were tested towards the reaction between triolein and butanol to produce butyl oleate. Pseudomonas cepacia lipase resulted to be the most active enzyme reaching 100% of conversion after 6h. Different operative conditions such as reaction temperature, water activity, and reagent stoichiometric ratio were investigated and optimised. These conditions were then used to investigate the effect of linear and branched short chain alcohols. Methanol and 2-butanol were the worst alcohols: the former, probably, due to its low miscibility with the oil and the latter because secondary alcohols usually are less reactive than primary alcohols. Conversely, linear and branched primary alcohols with short alkyl chains (C(2)--C(4)) showed high reaction rate and conversion. A mixture of linear and branched short chain alcohols that mimics the residual of ethanol distillation (fusel oil) was successfully used for oleic acid ester synthesis. These compounds are important in biodiesel mixtures since they improve low temperature properties.

Alcohols↗