Flunisolide HFA.

Abstract

Flunisolide is a synthetic corticosteroid approved for the treatment of persistent asthma and delivered by means of a metered-dose inhaler (MDI). A new formulation of flunisolide, using hydrofluoroalkane (HFA) as a propellant, has been developed to comply with the mandated worldwide phase-out of ozone-depleting chlorofluorocarbon (CFC) propellants. Aerosol particle size in the new flunisolide HFA solution is smaller than the flunisolide CFC suspension (1.2 vs 3.8 microm mass median aerodynamic diameter). Aerosol particle size is a key element in determining lung deposition and the regional distribution of inhaled medication within the lung. In addition, the flunisolide HFA MDI has been redesigned to include a built-in spacer. These features have improved distal lung deposition. Flunisolide HFA, at one-third the dosage (170 and 340 microg twice daily), had similar efficacy to flunisolide CFC (500 and 1000 microg twice daily) and significantly greater efficacy than placebo in a randomized, double-blind, placebo-controlled, 12-week study in patients with mild to moderate asthma. Flunisolide HFA was well tolerated in all trials. A long-term study found no suppression of adrenal function and minimal systemic effects were observed both in adults and children.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Waugh, Karen L Goa. 2002. Flunisolide HFA.. https://doi.org/10.1007/bf03256630

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A comparison of two methods to determine the solubility of compounds in aerosol propellants.

A new on-line reverse phase HPLC method for determining the solubility of compounds in propellant based metered dose inhaler (MDI) formulations was compared with a conventional method. The new method employs a direct injection from a MDI vial into the needle injector port of a manual injector. To evaluate the two methods, beclomethasone dipropionate (BDP), 5,5-diphenyl hydantoin and 3,3'-diindolylmethane, were used as model compounds in propellant HFA-134a. Comparison was performed by analyzing known and unknown concentrations of BDP in various combinations of HFA-134a and ethanol. In addition, the solubility of 5,5-diphenyl hydantoin and 3,3'-diindolylmethane were determined in HFA-134a using both the new and the conventional methods. The two methods were found to be in good agreement with each other, with the new direct injection technique offering enhanced precision and accuracy along with considerable reduction in analysis time.

Aerosol Propellants↗

Heat-transfer dynamics during cryogen spray cooling of substrate at different initial temperatures.

Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser dermatologic therapy. However, the dominant mechanisms of heat transfer during the transient cooling process are incompletely understood. The objective of this study is to elucidate the physics of CSC by measuring the effect of initial substrate temperature (T0) on cooling dynamics. Cryogen was delivered by a straight-tube nozzle onto a skin phantom. A fast-response thermocouple was used to record the phantom temperature changes before, during and after the cryogen spray. Surface heat fluxes (q") and heat-transfer coefficients (h) were computed using an inverse heat conduction algorithm. The maximum surface heat flux (q"max) was observed to increase with T0. The surface temperature corresponding to q"max also increased with T0 but the latter has no significant effect on h. It is concluded that heat transfer between the cryogen spray and skin phantom remains in the nucleate boiling region even if T0 is 80 degrees C.

Aerosol Propellants↗

Medical aerosol propellant interference with infrared anaesthetic gas monitors.

BACKGROUND: 1,1,1,2 Tetrafluoroethane is a hydrofluoroalkane (HFA) that is replacing chlorofluorocarbons (CFC) as a medical aerosol propellant in an attempt to reduce damage to the ozone layer. This study compared the effects of HFA- and CFC-based inhalers on four anaesthetic gas monitoring systems. METHODS: The HFA- and CFC-based inhalers were activated in close proximity to the sample line of two Datex Ohmeda, an Agilent and a Siemens infrared anaesthetic agent monitoring systems. The effects were recorded on each system for five common anaesthetic agents. RESULTS: The HFA inhaler caused either maximal false positive readings (with the exception of desflurane) or transient measurement failure on all systems. The Datex Ohmeda AS/3 system misidentified the HFA inhaler as carbon dioxide at low concentration (2 +/- 0 mm Hg). The CFC-based inhaler caused a minor false-positive reading (0.4 +/- 0%) for halothane only on the Datex Ohmeda AS/3 system only and was misidentified as carbon dioxide at 33.3 (sd 2.1) mm x Hg and 22.4 (8.9) mm x Hg by the Agilent and Siemens systems. CONCLUSIONS: The HFA inhaler adversely affected all equipment tested. The infrared spectra of HFA and the common anaesthetic gases have considerable overlap at the 8-12 microm range that is not shared by the CFCs. The differences in spectral overlap explain the different effects of the HFA and CFC propellants. Anaesthetic gas concentration data may be erroneous using the HFA-based inhalers.