Search PubMed⌕ Search

PubMed · 14716618

Arrhythmia database for algorithm testing: surface leads plus intracardiac leads for validation.

Abstract

Ann Arbor Electrogram Libraries (AAEL) is a database of over 500 electrocardiographic recordings made during clinical electrophysiology studies over a period of 15 years. These data are used by university researchers and cardiac device research and development laboratories to develop and test arrhythmia detection algorithms. The AAEL library is in use by all major implantable cardioverter defibrillator manufacturers as well as several Automated External Defibrillator developers. In 1996, the USFDA Center for Devices and Radiological Health licensed a portion of Volumes I for proposed device testing. The data consist of 7 channels of signals: surface leads I, III, V1, an intra-atrial high right atrium (bipolar), an intra-atrial high right atrium (unipolar), an intraventricular right ventricular apex (bipolar), and intraventricular right ventricular apex (unipolar) from the distal catheter electrode. Data were recorded under careful engineering quality control continuously (30 min-1.5 hr) on FM magnetic tape at a tape speed of 3.75 in/s after signal amplification at a filter setting of 1-500 Hz. Amplifier gain and filter settings were held constant during the entire recording procedure and a 1 mV calibration signal was entered as a reference at the time of recording. All patient recordings contain a baseline sinus rhythm, and subsequently induced ventricular tachycardia and/or ventricular fibrillation, or less frequently, supraventricular tachycardia, atrial tachycardia, and/or atrial fibrillation. Data are typically made available in digitized format (1,000 Hz); digital or FM recordings are also available. AAEL recordings are the only widespread intracardiac test files in the industry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janice M Jenkins, Richard E Jenkins. 2003. Arrhythmia database for algorithm testing: surface leads plus intracardiac leads for validation.. https://doi.org/10.1016/j.jelectrocard.2003.09.041

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Time to resumption of driving after implantation of an automatic defibrillator (from the Dual chamber and VVI Implantable Defibrillator [DAVID] trial).

The time to resumption of driving after insertion of an implantable cardioverter-defibrillator (ICD) was evaluated in the Dual Chamber And VVI Implantable Defibrillator trial. Most patients were advised not to drive for 3 to 6 months after the ICD was implanted. Patients were surveyed at 3-, 6-, or 9-month intervals to characterize their driving habits, with 101 of 137 (73.7%), 98 of 146 (67.1%), and 79 of 135 (58.5%) responding. Of respondents, 82% recalled being told not to drive for a specified time after ICD implantation. These patients generally obeyed recommendations (association between recommended time and time of resumption, p <0.001) from medical personnel.

Arrhythmias, Cardiac↗

Diuretic usage in heart failure: a continuing conundrum in 2005.

Several large well-designed clinical trials have shown that the use of diuretics is beneficial in patients with hypertension. However, similarly robust data regarding their role in chronic heart failure are lacking. Historically, diuretics were developed for treatment of sodium and water retention in oedematous disorders and clinically, they remain the most potent drugs available to relieve symptoms and eliminate oedema in the congested patient with heart failure. In the non-congested patient, however, diuretics continue to be used on a purely clinical basis without sufficient characterization of benefits, adverse effects, and potential influence on mortality. There are also concerns that chronic diuretic usage can cause adverse vascular effects, unfavourable neuroendocrine activation, electrolyte imbalances, and life-threatening arrhythmias. In this article, we review the limited evidence available regarding the benefits and perils of using diuretics in heart failure.

Arrhythmias, Cardiac↗