Search PubMed⌕ Search

PubMed · 14708757

C-arm-based three-dimensional navigation: a preliminary feasibility study.

Abstract

OBJECTIVE: With the new Siremobil Iso-C3D C-arm, three-dimensional (3D) datasets can be acquired intraoperatively in near-real time. Preliminary studies investigated the advantages of this system for depiction in joint and spinal surgery. Three-dimensional navigation seems feasible using the DICOM dataset of the Siremobil Iso-C3D in navigation devices. An experimental study was designed to investigate the feasibility and accuracy of this new technique. MATERIALS AND METHODS: After implantation of fiducial markers (titanium mini-screws, Leibinger), a Siremobil Iso-C3D C-arm with standard imaging options was used to acquire pre-interventional 3D datasets of the specimens. These isotropic voxel data were transferred via DICOM to a medivision navigation system using the spine module. After registration of the fiducials, a total of 20 pedicle screws were implanted (in 4 artificial-bone vertebral bodies and 6 cadaver vertebrae in situ) with the use of the navigation system in real-time mode. Post-interventionally, Iso-C3D and CT scans were obtained to control for implant position in the cadaver study. RESULTS: Fiducial marker implantation and registration require a special protocol to ensure correct identification and patient orientation in the DICOM dataset. The obtained accuracy was within 2 mm. Post-interventional imaging of the cadaveric vertebrae showed 10 of 12 screws to be correctly placed, with the other two in marginal intraosseous positions. CONCLUSIONS: Three-dimensional navigation with the Siremobil Iso-C3D data set is feasible, the accuracy being comparable to that of CT-based navigation and adequate for clinical interventions. Fiducial marker-based registration allows navigation of different bones in the same dataset without additional 3D scanning. This method is very useful as an additional tool in registration-free Iso-C3D-based navigation, since the navigation system allows the use of only one dynamic reference base (DRB).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ekkehard Euler, Sandro Heining, Christian Riquarts, Wolf Mutschler. 2003. C-arm-based three-dimensional navigation: a preliminary feasibility study.. https://doi.org/10.3109/10929080309146101

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimental validation of noninvasive referencing in navigated procedures on long bones.

Navigation procedures in orthopedic surgery require fixation of reference markers to the anatomic region of interest. Inadequate fixation might lead to micromotion or loosening of the reference marker, consequently causing registration failures or errors in navigation. Osseous rigid fixation is usually achieved by minimally invasive Schanz screws or pins. The goal of this study was to evaluate a non invasive external fixation device, a headband so far used in cranial navigation, as an alternative invasive fixation technique to reference markers in the femur. A common navigation system with an adapted trauma software application was used to track the positions of the soft tissue-attached headband relative to an invasive reference marker on the femur during manipulations of the thigh. Relative translative and rotational movements of the headband were measured during defined movements of the hip and knee and manipulations of the headband itself. The results revealed high translative and rotational movements, up to 6 mm and 3 degrees , respectively, due to minor manipulations of the affected lower extremity. Noninvasive soft tissue fixation with a headband does not allow rigid fixation for accurate navigated registration or operative procedures at the femur. Necessary intraoperative movements or manipulations would cause substantial registration failures. Invasive fixation techniques with screws or pins are still the method of choice.

Bone Screws↗

Safety of computer-assisted surgery for cannulated hip screws.

Computer-assisted orthopaedic surgery has developed considerably during the past few years. Several manufacturers produce hardware and software for use in trauma surgery. Validation of these systems before clinical application is mandatory to be sure they work accurately and safely. The accuracy of surgical performance is highly correlated with the cut-out percentages of hip screws. In a standardized operative setting, three cannulated hip screws were inserted in each of 20 sawbones. The screws were positioned either by fluoroscopic navigation technique or by conventional operative technique depending on randomization. Our primary aim was to assess whether computer-navigated screw fixation is equally safe compared with conventional screw fixation using fluoroscopy. To determine safety, we investigated number of drilling attempts, screw position, and radiation time. Secondary to these safety parameters, we also compared the operating time between the two procedures to assess the efficiency of computer navigation. Statistical analysis showed no differences regarding accuracy of screw position. Computer-assisted surgery resulted in fewer drilling attempts and less radiation time, with a similar operation time. We believe the currently used navigation system is safe and accurate.

Bone Screws↗

Techniques of posterior C1-C2 stabilization.

Instability of the atlantoaxial complex may result from inflammatory, traumatic, congenital, neoplastic, or degenerative disorders and often requires surgical stabilization. Initial dorsal wiring techniques allow safe fixation but require rigid external immobilization and have been associated with high fusion failure rates. Rigid screw fixation techniques including transarticular screw fixation and C1-C2 rod-cantilever fixation offer higher fusion rates and less need for rigid immobilization but are more technically demanding. C1-C2 fixation using crossing C2 laminar screws offers rigid fixation but without the technical demands of C2 pars placement. The history and techniques of dorsal fixation of the atlantoaxial complex are reviewed, and the success rates and complications of each are discussed.

Bone Screws↗