Data-processing method to reduce error coefficients for membrane-based analytical systems. 1. Amperometric-based sensor evaluated for quantification of oxygen.

Abstract

This paper describes the use of a predictive, curve-fitting method to reduce the effects of experimental variables on results obtained with membrane-based devices. Multipoint data from the transient regions of responses are used with suitable models and curve-fitting methods to predict the signal that would be measured for the system at equilibrium. The resulting equilibrium response usually is much less dependent on experimental variables than the transient responses used to predict it. The approach is evaluated for the membrane-based amperometric electrode for oxygen. Current vs time data are used to predict the equilibrium current expected when oxygen concentrations are the same on both sides of the membrane. Predicted equilibrium currents vary linearly with oxygen concentration. Relative to the more common steady-state method, the sensitivity of the predictive method is about 5-fold higher, the measurement time is about 17-fold shorter and the dependencies on membrane thickness and stirring rate are 125- and 8-fold lower, respectively. Pooled standard deviations (n = 40) correspond to uncertainties in oxygen concentration of about 0.009 mmol L-1.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C E Uhegbu, H L Pardue. 1992-10-15. Data-processing method to reduce error coefficients for membrane-based analytical systems. 1. Amperometric-based sensor evaluated for quantification of oxygen.. https://doi.org/10.1021/ac00044a014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of sulfate concentrations and tracer/tracee ratios in biological fluids by electrospray tandem mass spectrometry.

A reproducible and very sensitive method is described for the quantitation of inorganic sulfate in biological fluids by negative electrospray ionization tandem mass spectrometry. After addition to the sample of (34)S-labeled sodium sulfate internal standard and deproteinization with methanol, interfering bicarbonate anions are removed by acidification and chloride and phosphate by means of a single filtration step. The tandem mass spectrometer is used in neutral loss mode to detect HSO(4)(-) ions free of interference from residual isobaric H(2)PO(4)(-) ions. Organic sulfates do not interfere with the measurement. Serum and urinary inorganic sulfate concentrations measured with this technique agree closely with determinations by ion-exchange chromatography with conductivity detection. Unlike the latter method, this technique does not require dedicated equipment. The method is also suitable for measuring the ratio of (34)S-labeled sulfate to unlabeled sulfate in serum and hence represents an attractive alternative for the use of the radioactive (35)S isotope in human studies of body composition and oxidation of sulfur-containing substrates to sulfate.

Chemistry Techniques, Analytical

Driving forces for phase separation and partitioning in aqueous two-phase systems.

A set of simple analytical equations, derived from the Flory-Huggins theory, are used to identify the dominant driving forces for phase separation and solute (e.g., protein) partitioning, in the absence and presence of added electrolyte, in every general class of aqueous two-phase systems. The resulting model appears to capture the basic nature of two-phase systems and all trends observed experimentally. Case studies are used to identify fundamental differences in and the magnitudes of enthalpic and entropic contributions to partitioning in polymer-polymer (e.g., PEG-dextran), polymer-salt, and thermoseparating polymer-water (e.g., UCON-water) two-phase systems. The model therefore provides practitioners with a better understanding of partition systems, and industry with a simple, fundamental tool for selecting an appropriate two-phase system for a particular separation.

Chemistry Techniques, Analytical

Consistent view of electrolytes in aqueous two-phase systems.

The effects of electrolytes in aqueous two-phase systems are investigated. It is shown that macroscopic and molecular models give a consistent view of electrolytes at interfaces. The electrostatic potential difference delta psi between coexisting phases is a common property at interfaces even though the phases are strictly electroneutral and delta psi can not be measured. It is shown how delta psi can be quantified under controlled conditions. Additionally, a molecular picture is presented based on computer simulations.

Chemistry Techniques, Analytical