Recent developments in micro-diffraction on protein crystals.

Abstract

Protein crystallography micro-diffraction and micro small-angle X-ray scattering at a third-generation synchrotron radiation source undulator beamline both require a compromise on beam size and beam divergence. Micro small-angle X-ray scattering requires in addition an as-close-as-possible angular approach to the direct beam, which is mainly limited by the beam divergence at the sample position. Both techniques have been developed at the ESRF microfocus beamline in a complimentary way. The development of a dedicated microgoniometer in the frame of an EMBL/ESRF collaboration has revealed the potential of micro-diffraction for protein crystallography and is a step in the quest for user friendly instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christian Riekel. 2003-11-28. Recent developments in micro-diffraction on protein crystals.. https://doi.org/10.1107/s090904950302541x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of FITC-cortisol via modulated supraparticle lighthouses.

Hormones are important bioactive compounds in blood and tissue that vary in concentration in response to stress and certain disease states. Establishing the changes in physiological hormone concentrations over time can lead to more effective diagnoses and perhaps a better understanding of the evolution of stress and disease. To monitor concentration over time, the sampling must be rapid and noninvasive; specimens such as saliva that require little effort to collect are preferred. However, more sensitive assay techniques are needed when compared to blood analysis since free hormone concentration in saliva is only a small fraction of the concentration in circulating blood. In this work, magnetic field-induced structures of paramagnetic particles are used as a solid substrate to demonstrate improved detection limits for a separation-free assay of cortisol. Once formed, the structures are subjected to a rotating magnetic field and this leads to two important features. First is the ability to utilize frequency and phase filtering (lock-in amplification) for the signal generated from surface-bound labeled species. Second is the improved mass transport of the antigen to the surface of the rotating structures. These two unique capabilities result in a quantifiable signal at a relatively low target antigen concentration. This method has been demonstrated with the detection of fluorescein isothiocyanate-labeled cortisol (FITC-cortisol) at a concentration of 300 pM.

Equipment Design↗

A new hermetic antenna for wireless transmission systems of implantable medical devices.

In implantable medical devices (IMDs), the need of telemetry systems able to provide wireless bidirectional communication to interrogate and remotely program the device, as well as to monitor the physiological status of the patient, is growing. The object of the present study was to evaluate a new hermetic antenna for wireless short-range transmission system for IMDs which would assure reliable long-term functioning due to the high level of hermeticity of antenna's housing that limits the influence of body tissue environment on transmitted signals. Experimental tests were conducted on three different prototypes to evaluate the most efficient antenna configuration for transmission both in the air and through a mixture simulating the human thorax. Further tests were performed to assess the influence of electro-catheters connected to IMDs on transmitted signals. Results showed that the hermetic antenna guarantees a good wireless transmission both in the air and through the human thorax simulator. The results also show that the presence of an electro-catheter can influence the effective radiated power (ERP) transmitted depending on its position in relation to the telemetric circuitry. Both a controlled increase of the ERP without exceeding the limits imposed by rules and the optimization of the tuning between the antenna and the transmitter can assure a reliable short-range transmission (several meters) using the new hermetic antenna proposed.

Equipment Design↗

Measurement of exercise ventilation by a portable respiratory inductive plethysmograph.

The purpose of this study was to evaluate the accuracy of a respiratory inductive plethysmograph (RIP) designed for ambulatory data collection during exercise by comparison to a pneumotachograph. Healthy young males (n=10) wore an elastic body garment embedded with inductance sensors encircling the rib cage and abdomen. Breathing frequency (f(R)), tidal volume (V(T)) and minute ventilation (V (I)) were monitored during 5min of rest, slow walking (3.7kmh(-1)), fast walking (6.1kmh(-1)) and slow running (8.9kmh(-1)) followed by an incremental treadmill test to exhaustion (14.4+/-2.7kmh(-1)). Mean f(R), V(T) and V (I) values were not statistically different between the two methods (P>0.05). Within each of the subjects at rest and different exercise intensities, the average coefficient of determination was high for f(R), V(T) and V (I) (R(2)=0.9233, 0.8743 and 0.9652, respectively) and the mean bias values were low (-0.102+/-2.91, 0.033+/-0.207 and -0.715+/-8.362, respectively). These data suggest that the ambulatory RIP provides reasonable estimates of ventilation during rest and exercise.

Equipment Design↗