Search PubMed⌕ Search

PubMed · 14623422

Pollution-preventing anionic lithographic inks.

Abstract

Lithographic printing presses use aliphatic and aromatic solvents for cleaning various surfaces, which are coated with the ink. The conventional printing inks also contain volatile solvents. During printing and cleaning operations, volatile organic compounds (VOCs) present in the inks and cleaning solvents are lost to the atmosphere by evaporation and these losses are quantifiable and alarmingly high. A new type of ink based on castor oil, which completely eliminates emissions of VOCs, has been developed. Synthesis of resins and the kinetics of washing of the ink, similar to the recently announced pollution-preventing ink [development of a VOC-free lithographic printing system. TAGA Proc., 324], with water at a slightly elevated pH are studied. A correlation between the mass-transfer coefficient characterizing the washing of ink and the experimental process variables is confirmed. New data are also reported on flake-formation dynamics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chandrakant S Maji, Ashok N Bhaskarwar. 2003-12-12. Pollution-preventing anionic lithographic inks.. https://doi.org/10.1016/j.jhazmat.2003.07.007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation.

Personal and area air samples were taken at a scrap lead smelter operation in a bullet manufacturing facility. Samples were taken using the 37-mm styrene-acrylonitrile closed-face filter cassette (CFC, the current US standard device for lead sampling), the 37-mm GSP or "cone" sampler, the 25-mm Institute of Occupational Medicine (IOM) inhalable sampler, and the 25-mm Button sampler (developed at the University of Cincinnati). Polyvinylchloride filters were used for sampling. The filters were pre- and post-weighed, and analyzed for lead content using a field-portable X-ray fluorescence (XRF) analyzer. The filters were then extracted with dilute nitric acid in an ultrasonic extraction bath and the solutions were analyzed by inductively coupled plasma optical emission spectroscopy. The 25-mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37-mm filters. The single reading from the 25-mm filters was adjusted for the nominal area of the filter to obtain the mass loading, while the three readings from the 37-mm filters were inserted into two different algorithms for calculating the mass loadings, and the algorithms were compared. The IOM sampler was designed for material collected in the body of the sampler to be part of the collected sample as well as that on the filter. Therefore, the IOM sampler cassettes were rinsed separately to determine if wall-loss corrections were necessary. All four samplers gave very good correlations between the two analytical methods above the limit of detection of the XRF procedure. The limit of detection for the 25-mm filters (5 microg) was lower than for the 37-mm filters (10 microg). The percentage of XRF results that were within 25% of the corresponding ICP results was evaluated. In addition, the bias from linear regression was estimated. Linear regression for the Button sampler and the IOM sampler using single readings and the GSP using all tested techniques for total filter loading gave acceptable XRF readings at loadings equivalent to sampling at the OSHA 8-hour Action Level and Permissible Exposure Limit. However, the CFC only had acceptable results when the center reading corrected for filter area was used, which was surprising, and may be a result of a limited data set. In addition to linear regression, simple estimation of bias indicated reasonable agreements between XRF and ICP results for single XRF readings on the Button sampler filters, (82% of the individual results within criterion), and on the IOM sampler filters (77% or 61%--see text), and on the GSP sampler filters using the OSHA algorithm (78%). As a result of this pilot project, all three samplers were considered suitable for inclusion in further field research studies.

Air Pollutants, Occupational↗

The 4-parameter lognormal (SB) model of human exposure.

This paper explores the 4-parameter lognormal distribution (or Johnson S(B) distribution) as a model for occupational exposures to airborne contaminants. This model can incorporate extreme values when they are known a priori, or alternatively, they can be estimated from the data. This additional flexibility may be of value in estimating background and/or maximum exposures, as well as improving the fitting process and subsequent estimation of mean exposures. In addition, the model is physically consistent with the definition of concentration and provides a basis for linking stochastic and deterministic exposure modeling approaches. There is some additional computational burden in estimating the mean and variance of exposure relative to the usual 2-parameter lognormal model.

Air Pollutants, Occupational↗

Total versus inhalable sampler comparison study for the determination of asphalt fume exposures within the road paving industry.

Exposure to asphalt fumes has a threshold limit value (TLV of 0.5 mg m(-3) (benzene extractable inhalable particulate) as recommended by the American Conference of Governmental Industrial Hygienists (ACGIH). This reflects a recent change (2000) whereby two variables are different from the previous recommendation. First is a 10-fold reduction in quantity from 5 mg m(-3) to 0.5 mg m(-3). Secondly, the new TLV specifies the "inhalable" fraction as compared to what is presumed to be total particulate. To assess the impact of these changes, this study compares the differences between measurements of paving asphalt fume exposure in the field using an "inhalable" instrument versus the historically used 'total' sampler. Particle size is also examined to assist in the understanding of the aerodynamic collection differences as related to asphalt fumes and confounders. Results show that when exposures are limited to asphalt fumes, a 1:1 relationship exists between samplers, showing no statistically significant differences in benzene soluble matter (BSM). This means that for the asphalt fume ACGIH TLV, the 'total' 37-mm sampler is an equivalent method to the "inhalable" method, referred to as IOM (Institute of Occupational Medicine), and should be acceptable for use against the TLV. However, the study found that when confounders (dust or old asphalt millings) are present in the workplace, there can be significant differences between the two samplers' reported exposure. The ratio of IOM/Total was 1.37 for milling asphalt sites, 1.41 for asphalt paving over granular base, and 1.02 for asphalt over asphalt pavements.

Air Pollutants, Occupational↗