Search PubMed⌕ Search

PubMed · 14621438

The 65/75 split.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cherilyn G Murer. 2003. The 65/75 split.. https://pubmed.ncbi.nlm.nih.gov/14621438/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: materials selection and evaluation.

The polyurethane elastomer (PU) Corethane 80A (Corvita) is being considered as the acetabular bearing material in a novel total replacement hip joint. The biostability of Corethane 80A was investigated in vitro (this work) and in vivo (reported separately) in a fully functioning ovine total hip arthroplasty (THA) model, with the PU as the bearing layer in a prototype compliant layer acetabular cup. The in vitro studies assessed the resistance of Corethane 80A to the main degradation mechanisms observed in PUs: hydrolysis, environmental stress cracking (ESC), metal ion oxidation (MIO) and calcification. The performance of the polycarbonate PU Corethane 80A was assessed alongside three other commercially available biomedical PUs: polyether PUs Pellethane 2363-80A (DOW Chemical) and PHMO-PU (CSIRO, not supplied as a commercial material) as well as polycarbonate PU ChronoFlex AL-80A (CardioTech). Chemical and structural variables that affect the properties of the materials were analysed with particular attention to the nature of the material's hard and soft segments. PU degradation was probed using a range of analytical tools and physical-testing methods, including mechanical testing, differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) and environmental scanning microscopy (ESEM). Corethane 80A displayed the best overall resistance to hydrolysis, ESC, MIO and calcification, followed by ChronoFlex 80A and PHMO-PU. Pellethane 80A was the least stable. This study provides compelling evidence for the biostability and effectiveness of Corethane 80A and points to its suitability for use as a compliant bearing layer in hip arthroplasty, and possibly also other joints.

Arthroplasty, Replacement, Hip↗

A special pool project for rehabilitation of hip and knee arthroprosthesis.

PURPOSE: The use of ankle or knee arthroprostheses is increasing and proper rehabilitation is needed after the surgery. We have designed a special pool where normal gait can take place under partly unweighted conditions, thus improving quality of therapy and reducing the length of stay. Underwater TV recording permits daily gait analysis. DESCRIPTION: Data are provided on pool shape, length and depth of the walkway, water conditions, safety and other facilities. The cost has been compared to commercial pools of the same type. CONCLUSION: The design permits accurate definition of stride parameters during rehabilitation which enables the programme to be optimized. The pool is cheaper than commercial ones but offers many more research possibilities. The Authors are glad to share their expertise freely upon request.

Arthroplasty, Replacement, Hip↗

Stability of hip hemiarthroplasties.

It has been stated in the literature that a bipolar hemiarthroplasty has a lower risk of dislocation compared to a unipolar hemiarthroplasty. As this statement has not been substantiated we undertook a systematic review of the literature of published articles from the last 40 years. In addition we used our own database of hip fractures. One hundred and thirty-three published articles were included in the review to give a total of 23,107 cases. The overall dislocation rate for all types of hemiarthroplasty was 791/23,107 (3.4%). An increased risk of dislocation was associated with a posterior surgical approach and the use of a cemented prosthesis. After adjustment for surgical approach and the use of cement there was no difference in risk of dislocation between unipolar and bipolar hemiarthroplasties. There was an increased risk of open reduction for a bipolar hemiarthroplasty.

Arthroplasty, Replacement, Hip↗